Full Product Manual

www.tnb.com
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
G-80
Shield-Kon
®
Shield Termination System
Wire Termination — Sta-Kon
®
Wire Termination & Insulation
CONNECTOR
& COLOR
CAT. NO.
SHIELD DIAMETER
METAL DIES
FOR ERG740
GROUND
WIRE
RANGE
APPLICATION TOOL
CAT. NO.
RSK101
1.27–1.78mm
(.050–.070 in.)
D-101A
(1) or (2)
Hand Tool
ERG740
#24 AWG Str.
Red
1.80–2.26mm
(.071–.089 in.)
D-101B
or (1)
#22 AWG Str.
2.29–2.54mm
(.090–.100 in.)
D-201C
RSK201
2.56–3.00mm
(.101–.118 in.)
D-201D
(1) or (2)
#22 AWG Str.
Blue
3.022–3.33mm
(.119–.131 in.)
D-201E
or (1)
#20 AWG Str.
3.35-3.63mm
(.132–.143 in.)
D-201F
3.66–4.11mm
(.144–.162 in.)
D-301G
(1) or (2)
RSK301
Yellow
4.14–4.70mm
(.163–.185 in.)
D-301H
#22 AWG Str.
or (1) or (2)
4.72–5.10mm
(.186–.201 in.)
D-301J
#20 AWG Str.
5.13–5.84mm
(.202–.230 in.)
D-401K
RSK401
5.87–6.35mm
(.231–.250 in.)
D-401L
(1) or (2)
#20 AWG Str.
Green
6.37–6.98mm
(.251–.275 in.)
D-401M
or (1)
#18 AWG Str.
7.01–7.62mm
(.276–.300 in.)
D-401N
Maintains voltage and is easy to install!
Shield-Kon
®
RSK Connectors
CAT. NO.
COLOR
DIMENSIONS (IN.)
THICKNESS
STD.
PKG.A B C D E
RSK-101 Red .31 .16 .18 .06 .15 .02 1,000
RSK-201 Blue .38 .22 .18 .06 .18 .02 1,000
RSK-301 Yellow .47 .28 .24 .07 .22 .03 1,000
RSK-401 Green .69 .43 .37 .08 .37 .03 500
Order multiple is std. pkg.
How to use connector die and tool selection chart:
1. Use a calibrated measuring tool lightly over shield for most
accurate measurement. Rotate shielded wire to pick up high
spots on cable. Use “Shield Diameter” column to match the
measured dimension.
2. Select connector and die for ERG740 tool.
Note: 1. Do not solder-dip ends of ground leads.
2. For ground wire combinations not covered
in table, consult Technical Service.
.59 - .64
INSULATION
.11
BOTH SIDES
GROUND
LEAD TRAP
A
E
B
C
D
Ground
Lead Trap
C
D
A
B
E
One-Piece Shield-Kon
®
Connectors & Die Selection Table