Full Product Manual
Table Of Contents
- Contents
- Overview
- Ring Terminals
- Flag Terminals
- Fork Terminals
- Pin Terminals
- Splice Connectors
- Wire Joints
- Heat-Shrinkable Terminals, Splices, Disconnects
- Disconnects and Male Tabs
- Luminaire Disconnects
- Ferrules
- Wire Termination Tools and Installation Kits
- Wire Termination Technical Information
- Shrink-Kon® Heat-Shrinkable Tubing
- Shrink-Kon® Splice Insulatorsand Insulating Covers
- Shrink-Kon® Installation Tools
- Shield-Kon® Shield Termination System
- Dragon-Tooth® Magnet WireTermination System
www.tnb.com
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
G-94
Dragon Tooth
®
Magnet Wire Termination System
Wire Termination — Sta-Kon
®
Wire Termination & Insulation
Splices
• Penetrate all standard copper and aluminum
magnet wire insulations
• Perfect for heavy Formvar, poly-thermaleze,
polyester and polyurethane insulations
CAT. NO.
DimeNsiONs (iN.)
CirCulAr
mil AreA
rOuND Wire
rANGe (AWG)
miN. mAx.
reCTANGulAr
Wire rANGe (iN.)
PkG.
QTy.A B C D* ThiCkNess WiDTh
214420 .43 .25 .22 .135 — 21 (4)–13 (2) — — 1000
220004 .17 .11 .08 .03 468–1,724 32–24** — — 8400
†
220001 .34 .17 .14 .09 1,277–4,205 26–17** .02–.04 .02–.09 3000
†
220002–TB .34 .25 .18 .09 2,985–6,687 24–14** .02–.05 .02–.10 3000
†
220006 .47 .25 .19 .09 5,162–12,330 16–12 .05–.08 .05–.16 2500
†
22l004 .15 .11 .09 .03 128–2,028 32–24** – – 1000
22l001 .32 .16 .16 .10 808–5,162 26–17** .02–.04 .02–.10 1000
22l002 .32 .25 .19 .10 2,048–9,110 24–15** .02–.05 .02–.11 1000
22l006 .44 .25 .22 .13 2,580–12,330 16–12 .05–.08 .05–.16 1000
22l008 .70 .50 .35 .13 12,960–30,550 18–14 .04–.06 .06–.38 100
22l009 .70 .55 .46 .20 36,120–86,000 16–5 .08–.18 .08–.38 100
22l010 .70 .78 .71 .22 69,750–173,090 (f) — .10–.23 (CU) .10–.18 (AL) .30–.63 50
210214s .63 .38 .37 .17 4,110–20,760 14(a)–10 .08–.09 .08–.18 250
204210s .69 .53 .53 .25 10,380–52,480 12(b)–4(e) .10–.16 .10 –.26 100
204210sh .69 .53 1.05 .48 20,760–104,960 12(c)–2(d) .10–.16 .10 –.26 100
22l009h .70 .55 .93 .37 72,000–132,000 16–5 .08–.18 .08–.38 100
220015 1.50 .88 .77 (e) 50,000–115,000 10–6 .100–.175 .300–.625 50
220019 1.50 .88 .85 (e) 110,000–175,000 6–2 .175–.250 .300–.625 25
220023 1.75 .88 .93 (e) 165,000–230,000 2–1/0 .250–.325 .300–.625 25
314118s .63 .38 .30 .14 3,260–12,330 15–13 .05–.06 .05–.18 250
220016 3.13 .88 .77 (e) 50,000–115,000 10–6 .100–.175 .300–.625 25
220020 3.13 .88 .85 (e) 110,000–175,000 6–2 .175–.250 .300–.625 25
220024 3.63 .88 .93 (e) 165,000–230,000 2–1/0 .250–.325 .300–.625 25
* Reference dimension. See installing die illustration for gauging.
** Not recommended for aluminum magnet wire finer than 21 gauge. (a) Four wires max. (b) Six wires max. (c) Six wires max. each barrel.
(d) Conductors heavier than #6 AWG require special dies. Contact Thomas & Betts for assistance.
(e) Crimping dies may not bottom. Connector height will depend on number and size of wires in barrel. Pump must deliver 9800 psi minimum.
(f) Copper CMA, aluminum CMA=52,136–124,561.
†
On a reel.
Note: Wire sizes and combinations shown have been tested to and meet or exceed Thomas & Betts specifications. Connectors may be suitable
for other wire sizes or combinations. Thomas & Betts sells these connectors with the understanding that the user will perform necessary
tests to determine their suitability for the intended purpose.
B
C
A
E
For special insulations, consult Technical Services.
Splices for copper and aluminum
magnet wire!
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
E
C
B
A