Product Manual

13
Caterpillar: Confidential Green
Overload Reset Button
This button can be used to clear an overload
condition without the need to stop and restart the
unit.
AC/DC Circuit Breakers
The generator comes equipped with AC (1) and DC
(2) circuit breakers that protect the unit and the load
from short circuit or overload conditions. If the circuit
breaker opens, determine why the circuit breaker
tripped before closing the circuit breaker.
120 VAC, 20 Amp, GFCI Duplex
The 120 VAC duplex receptacle is protected against
overload by a 20 Amp push to reset circuit breaker. It
also provides protection via a Ground Fault Circuit
Interruptor (GFCI) with press to Test and Reset
buttons. Use the receptacle to power a NEMA 5-20,
120 VAC, single phase, 60 Hz electrical load requiring
20 Amps of current.
Use only high quality, well insulated, 3-wire grounded
cords rated for 125 V at 20 Amps (or greater). Keep
extension cords as short as possible (less than 15
feet) to prevent voltage drop and overheating of wires.
120 VAC, 30 Amp, Locking
The 120 VAC locking outlet is protected against
overload by a 30 Amp push to reset circuit breaker.
Use a NEMA L5-30 plug with this receptacle (rotate
to lock or unlock). Use the receptacle to power a 120
VAC, single phase, 60 Hz, single phase, 60 Hz
electrical load requiring up to 27 Amps of current.
12 Volt DC
The generator comes equipped with a 12 volt DC
output capable of providing 8.3 Amps of current, via
the supplied 12 volt charging cable.
USB Receptacles
The generator comes equipped with a double USB
receptacle. The top is a 5V 1A USB port and the
bottom is a 5V 2.1A USB port.
Low Oil Level Shutdown
The generator is equipped with a low oil level
shutdown that is designed to protect the engine from
damage caused by an insufficient amount of oil in
the crankcase. When the oil level in the crankcase
falls below the safe operating limit the low oil level
light will illuminate and the engine will automatically
shutdown.