STORAGE
When a generator is in storage, air may condense
and moisture may appear on the windings. In order to
minimize condensation, always store the generator in
a dry area. Cover the generator with a protective
cover that extends to the ground. The cover should
remain loose around the generator to allow proper
ventilation.
The generator must not be stored in ambient
temperatures greater than 131
o
F (55
o
C) as this can
damage the CO DEFENSE
TM
(if equipped).
Wait until the generator has cooled before covering it.
NEVER operate the genrator with the cover installed.
It could ignite and cause damage.
Storage for 1 to 3 months
Remove any dirt, rust, grease, and oil from the
generator. DO NOT use a pressure washer to clean
the generator. Inspect the exterior. Make any
necessary repairs.
Add fuel stabilizer to the fuel tank to prevent the
gasoline from going bad. Start and run the engine for
5 minutes to ensure that the fuel stabilizer has been
pulled in to the carburetor. Shut off the engine and
allow the engine to cool.
Turn the generator switch to the off “O” position.
Move the generator to the storage place.
Cover the generator.
Storage for more than 3 months
Remove any dirt, rust, grease, and oil from the
generator. DO NOT use a pressure washer to clean
the generator. Inspect the exterior. Make any
necessary repairs.
Gasoline is extremely flammable and is
explosive under certain conditions. Drain the fuel
in a well-ventilated area with the engine stopped
and cool. Never smoke or allow flames or sparks
in the area during
this procedure.
Remove the fuel cap and carefully turn the generator
over to pour the gasoline into an appropriate
container. Reinstall the fuel cap, remove any fuel that
may have spilled onto the generator, then start and
run the engine until the engine stops to allow the fuel
to drain from the fuel lines, carburetor, and engine
system.
Change the engine oil. Refer to Engine Oil – Change.
Remove the spark plug and pour a small amount of
oil into the cylinder. Install the spark plug but do not
install the spark plug boot.
Turn the generator switch to the off “O” position.
Move the generator to the storage place.
Attach the trickle charger to the port on the control
panel and to standard AC power to keep the
generator battery fully powered for easy start after
storage. Disconnect the battery charger once the
battery is fully charged (indicated by a green light on
the charger)
Cover the generator.