Installation

Option 2: Horizontal Wall Venting
Side Wall
Cap
Option 1: Vertical Roof Venting
Roof Cap
This range hood is factory set for venting through the roof or wall.
Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow
is needed.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,
attics or garages. All exhaust must be ducted to the outside.
Use metal/aluminum duct work only.
Fasten all connections with sheet metal screws and tape all joints with certified duct tape or
equivalent.
Use caulking to seal exterior wall or roof opening around the cap.
IMPORTANT:
Pg 7
Venting Methods
Remove grease filters from the hood.
Position the charcoal filters onto the side of the motor, aligning the mounting points, turn
until it locks. Re-install aluminum filters.
Charcoal filters must be replaced after 120 hours of use (or approximately every 2 to 3
months based on the average of 1 to 2 hours of daily cooking time). Available at your local
resellers.
NOTE:
1.
2.
3.
Charcoal Filter Installation