Brochure

162
www.centuryelectricmotors.ca
Three Phase ODP Motors
Features:
Ball Bearings
Continuous Duty
Dripproof
Squirrel Cage
Energy Efficient $
Rigid Base
Applications:
Pumps, fans, compressors, conveyors.
Full Load Service Stock Insul. “C”
HP RPM Volts Amps Factor Frame Number Type Class Protector Dim. Efficiency Notes
7 1/2 3490 230/460 17.2/8.6 1.15 184T E205
J
E+3(NP) F None 15.6 90.2
7 1/2 1745 200 22.3 1.15 213T E302M
J
E+ F None 17.5 88.5
7 1/2 1760 200 22.3 1.15 213T E316
J
E+3(NP) F None 17.5 91.7 8
7 1/2 1760 230/460 19.4/9.7 1.15 213T E317
J
E+3(NP) F None 17.5 91.7 8
7 1/2 1750 575 7.5 1.15 213T E925
J
E+3(NP) F None 17.5 91.0
7 1/2 1175 230/460 21.0/10.5 1.15 254T E496
J
E+3(NP) F None 22.4 90.2
10 3520 230/460 22.0/11.0 1.15 213T E392
J
E+3(NP) F None 16.8 91.7
10 1745 200 30.8 1.15 215T E303
J
E+ F None 17.3 89.5 8
10 1755 200 29.0 1.15 215T E331
J
E+3(NP) F None 17.5 91.7 8
10 1755 230/460 25.2/12.6 1.15 215T E397
J
E+3(NP) F None 17.3 91.7 8
10 1755 575 10.1 1.15 215T E926
J
E+3(NP) F None 17.3 91.7 8
10 1740 575 10.3 1.15 215T E325
J
E+3(NP) F None 17.3 89.5
10 1175 230/460 27.4/13.7 1.15 256T E497
J
E+3(NP) F None 23.9 91.7
15 3500 230/460 32.8/16.4 1.15 215T E393
J
E+3(NP) F None 17.5 91.7
15 1750 200 42.2 1.15 254T E454V1
J
E+ F None 22.1 91.0
15 1770 200 43.4 1.15 254T E450
J
E+3(NP) F None 22.1 93.0
15 1770 230/460 37.8/18.9 1.15 254T E451
J
E+3(NP) F None 22.1 93.0
15 1770 575 15.1 1.15 254T E927
J
E+3(NP) F None 22.1 93.0
15 1165 200-230/460 47.5-42.0/21.0 1.15 284T E511
J
E+ F None 24.2 90.2 1
15 1170 230/460 43.0/21.5 1.15 284T E586M
J
E+3(NP) F None 24.3 91.7
Notes: Continues on next page
1. To be discontinued when stock is depleted
8. NEMA Design A
Performance at 200 or 208 volts may not be in accordance with NEMA standards.
Standard, EPAct CC001A
(E-Plus
®
motors) and Premium
(E-Plus
®
3 motors) Efficiency
40°C Ambient
60 Hz
NEMA Design B
E-Plus
®
Motors meet the require-
ments of the Energy Policy Act of
1992. E-Plus
®
3 motors exceed the
requirements of the Energy Policy
Act of 1992. E+3(NP) is NEMA
Premium Efficient.
Continued from previous page
E331
Motors specially designed, tested and warranted to
be Corona-Free for compatible inverter duty are
marked on this page with a J. See page 4 and 5
of this catalog for more Speed Engineered
®
motors
information.
E205