Brochure

168
www.centuryelectricmotors.ca
Features:
Ball Bearings
Continuous Duty
Squirrel Cage
Energy Efficient $
Rigid Base
No Protector
Applications:
Pumps, fans, compressors, conveyors.
Full Load Service Stock Insul. Cast “C”
HP RPM Volts Amps Factor Frame Number Type Class Iron Dim. Notes
1/4 1725/1425 208-230/460 1.4-1.5/.75 1.00 48Y H201A B 8.5 6,118
1/4 1140 200-230/460 1.3-1.2/.6 1.15 56 H205 B 10.1 14
1/3 3450 200-230/460 1.3-1.4/.7 1.15 56 H238 B 9.8 14
1/3 1725/1425 208-230/460 1.1-1.1/.6 1.00 48Y H261A B 8.7 6,118
1/3 1725/1425 200-230/460 1.2-1.2/.6 1.15 56 H263L B 10.5 6,14, New!
1/3 1725 200-230/460 1.2-1.2/.6 1.15 56 H688L B 11.0 New!
1/3 1140 200-230/460 1.8-1.6/.8 1.15 56 H268 B 11.1 14
1/3 1140 200-230/460 1.9-1.8/.9 1.50 56 H1040 B 12.2 171,346,118
1/2 3450 200-230/460 1.9-1.8/.9 1.15 56 H271 B 9.8 14
1/2 1725 200-230/460 1.6-1.8/.9 1.15 56 H274V1 B 11.1 14, New!
1/2 1725 208-230/460 1.6-1.8/.9 1.15 56 H868L B 11.0 New!
1/2 1725 575 0.7 1.15 56 H276 B 11.1 1,14
1/2 1725 575 0.7 1.25 56 H276L B 11.1 14, New!
1/2 1140 200-230/460 2.1-2.0/1.0 1.15 56 H280 B 11.1 14
1/2 1140 575 0.7 1.00 56 H249 A 11.1 14
3/4 3450 200-230/460 2.5-2.4/1.2 1.15 56 H448 B 11.1 14
3/4 1725 200-230/460 2.3-2.4/1.2 1.15 56 H580L B 11.4 14, New!
3/4 1725 200-230/460 2.5-2.4/1.2 1.15 56 H869L B 11.0 New!
3/4 1725 575 0.8 1.15 56 H461L B 12.2 14, New!
3/4 1140 200-230/460 3.2-3.2/1.6 1.15 56 H468 B 12.2
1 3450 200-230/460 3.2-3.0/1.5 1.15 56 H505 B 11.2
1 3450 575 1.15 1.15 56 H517 B 11.2
1 1740 200 3.4 1.15 143T T55026 J E+3(NP) F 13.2 11,363,365
1 1725 200-230/460 3.3-3.2/1.6 1.15 56 H524L B 11.7 New!
1 1730 230/460 2.8/1.4 1.15 143T T57026 J E+3(NP) F 13.2 11,361,363
1 1725 575 1.4 1.15 56 H525L B 11.6 New!
1 1730 575 1.1 1.15 143T T59026 J E+3(NP) F 13.2 11,363,365
1 1140 200-230/460 4.2-3.8/1.9 1.15 56H H528 B 13.4
1 1140 230/460 3.4/1.7 1.15 145T T57051 J E+3(NP) F 13.2 11,361,363
1 1140 575 1.4 1.15 145T T59051 J E+3(NP) F 13.2 11,363,365
Notes: Continues on next page
6. 60/50 Hz
11. C Flange kit available
14. Totally enclosed non-ventilated
118. TEAO
171. Motor is thermally protected
346. 65 degree C ambient
361. 9 leads
363. Double shielded bearings with no regreasing provisions
365. 3 leads
Three Phase Totally Enclosed Motors
H505
Published efficiency on tri-voltage rated motors applies at 230/460 volts.
Performance at 200 or 208 volts may not be in accordance with NEMA standards.
Published efficiency on 200-208 volt motors applies at 200 volts.
Motors specially designed, tested and warranted to
be Corona-Free for compatible inverter duty are
marked on this page with a J. See page 4 and 5
of this catalog for more Speed Engineered
®
motors
information.
Standard, EPAct CC001A
(E-Plus
®
motors) and Premium
(E-Plus
®
3 motors) Efficiency
40°C Ambient
60 Hz
E-Plus
®
Motors meet the require-
ments of the Energy Policy Act of
1992. E-Plus
®
3 motors exceed the
requirements of the Energy Policy
Act of 1992. E+3(NP) is NEMA
Premium Efficient.