Brochure

170
www.centuryelectricmotors.ca
Three Phase TEFC Motors
Features:
Ball Bearings
Continuous Duty
Squirrel Cage
Energy Efficient $
Rigid Base
NEMA Design B
No Protector
Applications:
Pumps, fans, compressors, conveyors, machine tools, designed to stand up to abusive treatment..moist, dirty, dusty and factory applications.
Full Load Service Stock Insul. Cast “C”
HP RPM Volts Amps Factor Frame Number Type Class Iron Dim. Efficiency Notes
3 3450 200-230/460 9.6-9.8/4.9 1.15 56HZ H738 B 15.0 15
3 3505 230/460 7.2/3.6 1.15 182T T57004 J E+3(NP) F 15.4 86.5 11,361,363
3 3520 575 2.9 1.15 182T T48004 J E+ F 15.4 85.5 11,363,365
3 3505 575 2.9 1.15 182T T59004 J E+3(NP) F 15.4 86.5 11,363,365
3 1735 200 8.7 1.15 182T T44029 J E+ F 15.4 87.5 11,363,365
3 1760 200 9.0 1.15 182T T55029 J E+3(NP) F 15.4 89.5 11,363,365
3 1745 230/460 7.8/3.9 1.15 182T T57029 J E+3(NP) F 15.4 89.5 11,361,363
3 1745 575 3.1 1.15 182T T59029 J E+3(NP) F 15.4 89.5 11,363,365
3 1165 230/460 8.6/4.3 1.15 213T T57054 J E+3(NP) F 19.4 89.5 11,362,363
3 1170 575 3.5 1.15 213T T59054 J E+3(NP) F 19.4 89.5 11,363,365
5 3505 230/460 11.6 1.15 184T T57005 J E+3(NP) F 15.4 88.5 11,361,363
5 3505 575 4.7 1.15 184T T59005 J E+3(NP) F 15.4 88.5 11,363,365
5 1745 200 14.7 1.15 184T T55030 J E+3(NP) F 15.4 89.5 11,363,365
5 1745 230/460 12.8/6.4 1.15 184T T57030 J E+3(NP) F 15.4 89.5 11,361,363
5 1745 575 5.1 1.15 184T T59030 J E+3(NP) F 15.4 89.5 11,363,365
5 1170 230/460 13.8/6.9 1.15 215T T57055 J E+3(NP) F 19.4 89.5 11,362,363
5 1170 575 5.5 1.15 215T T59055 J E+3(NP) F 19.4 89.5 11,363,365
Notes: Continues on next page
11. C Flange kit available
15. 56HZ = 7/8” keyed X 2 5/16” shaft
361. 9 leads
362. 12 lead - capability for Y Start-Delta Run
363. Double shielded bearings with no regreasing provisions
365. 3 leads
Published efficiency on tri-voltage rated motors applies at 230/460 volts.
Performance at 200 or 208 volts may not be in accordance with NEMA standards.
Published efficiency on 200-208 volt motors applies at 200 volts.
Standard, EPAct CC001A
(E-Plus
®
motors) and Premium
(E-Plus
®
3 motors) Efficiency
40°C Ambient
60 Hz
TEFC
E-Plus
®
Motors meet the require-
ments of the Energy Policy Act of
1992. E-Plus
®
3 motors exceed the
requirements of the Energy Policy
Act of 1992. E+3(NP) is NEMA
Premium Efficient.
Continued from previous page
Motors specially designed, tested and warranted to
be Corona-Free for compatible inverter duty are
marked on this page with a J. See page 4 and 5
of this catalog for more Speed Engineered
®
motors
information.
H738