Brochure

230
www.centuryelectricmotors.ca
Century® Industrial DC T-Pak Motor Tachometer Packages 9505
Integral PMDC Motor with On-Board 50V/1000 RPM Tachometer for Closed Loop
Motor Speed Control Systems – TEFC Removable Base 1725 & 1750 RPM – UL
Class F Insulation Capable of 100:1 Speed Range 1/4 thru 3 HP
Features:
Ball Bearings 40°C Ambient “C” Bracket
UL and CSA Approvable SCR Rated Skewed Armatures for Smooth, Quiet Operation
Current Current Full Load Stock Base/ Insul. “C”
HP RPM Armature Field Volts Amps Frame Number Mounting Enclosure Class Dim. Notes
90 Volt Armature • Permanent Magnet Field
1/4 1725 90 3.0 56C D750 RemovableBase TEFC F 12.7 1
1/3 1725 90 2.8 56C D751 RemovableBase TEFC F 13.1 1
1/2 1725 90 5.4 56C D752 RemovableBase TEFC F 14.9 1
3/4 1725 90 8.1 56C D753 RemovableBase TEFC F 16.9 1
180 Volt Armature • Permanent Magnet Field
1 1725 180 5.4 56C D757 RemovableBase TEFC F 18.9 1
2 1750 180 10.0 143TC D759 RemovableBase TEFC F 19.9 1
3 1750 180 14.5 143TC D760 RemovableBase TEFC F 22.9 1
Century® Industrial Direct Current Motors
For Rectified Power Dripproof & Enclosed – Rigid Base – 3500 & 1750 RPM
20:1 Speed Range at Constant Torque 1/4 thru 5 HP
Features:
Ball Bearings 40°C Ambient Removable feet CSA Approved
Type DN Shunt Wound NEMA “C” Bracket SCR Rated
Applications: For use with SCR, controllers on conveyors, machine tools, printing presses, and other industrial speed applications.
Current Current Full Load Stock Base/ Insul. “C”
HP RPM Armature Field Volts Amps Frame Number Mounting Enclosure Class Dim. Notes
90 Volt Armature • 100/50 Volt Field
1/4 1750 2.69 .32/.64 100/50 2.69 56C D904 RigidBase TENV F 10.8 1
1/3 1750 3.43 .42/.84 100/50 3.43 56C D906 RigidBase TENV F 11.7 1
 1/2 3500 5.10 .24/.48 100/50 5.1 56C D552 RigidBase TENV F 11.7 1
1/2 1750 4.95 .36/.72 100/50 4.95 56C D908 RigidBase TENV F 12.6 1
3/4 1750 7.40 .70/1.40 100/50 7.4 56C D909 RigidBase ODP F 12.6 1
3/4 1750 7.35 .73/1.46 100/50 7.35 56C D910 RigidBase TEFC F 14.9 1
1 1750 9.68 1.0/2.0 100/50 9.68 56C D912 RigidBase TEFC F 15.7 1
180 Volt Armature • 200/100 Volt Field
1/2 1750 2.45 .18/.36 200/100 2.45 56C D708 RigidBase TENV F 12.6 1
3/4 1750 3.73 .36/.72 200/100 3.73 56C D710 RigidBase TEFC F 14.8 1
1 1750 4.85 .36/.72 200/100 4.85 56C D711 RigidBase ODP F 14.4 1
1 1750 4.89 .38/.76 200/100 4.89 56C D712 RigidBase TEFC F 15.7 1
1 1/2 1750 7.45 .36/.72 200/100 7.45 184AC W245 RigidBase ODP F 15.2 1
1 1/2 1750 7.25 .61/1.22 200/100 7.25 187AC W244 RigidBase TENV F 17.2 1
2 1750 9.90 .50/1.00 200/100 9.9 185AC W261 RigidBase ODP F 15.9 1
2 1750 9.50 .75/1.50 200/100 9.5 189AC W260 RigidBase TENV F 20.2 1
5 1750 24.50 .85/1.70 200/100 24.5 189AC W281 RigidBase ODP F 20.2 1
Notes:
1.Itemtobediscontinuedwhenstockisdepleted
If base is removed, bolt holes must be plugged in order to maintain NEMA Totally-Enclosed standards.
If base bolts are used without base, use a 1/4” thick washer to prevent interference with motor rotation.
D752