Operating Manual Direct Vent/Natural Vent Gas Heater Jefferson

3232
Jefferson Direct Vent/Natural Vent Gas Heater
30004177
NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP-
PLIED WITH THE APPLIANCE, MUST BE RE-
PLACED, IT MUST BE REPLACED WITH TYPE
SF-2, 200°C WIRE OR ITS EQUIVALENT.
FAN JUNCTION BOX
FA
N
POWER
CORD
Strain Relief
Chassis Ground
BL
K
GRN
GRN
WHT
ON / OFF
Rheostat
Chassis
Ground
RHEOSTAT / SNAPSTAT
BOX
Snapstat
BLK
B
L
K
BLK
BLK
BL
K
WHT
ST153
rdv connections diag.
10/99
Fig. 64 Fan circuit.
MOTOR
SNAPSTAT
ON/OFF
RHEOSTAT
WHT
WHT
BLK
BLK
BLK
GRN
BLK
ST236
FK26 wiring diagram
12/99
Schematic Diagram
ST236
ST153
Wiring Diagrams
ST124c
Fig. 62 On/off switch and optional thermostat circuit.
Optional Thermostat
Wiring
On/Off Switch
Wiring
ST124b
OFF
ON
Thermostat
(Optional)
Therm
opile
Black
Black
Millivolt
Gas Valve
St124b
on/off/switch
wiring
1/11/00 djt
TP/TH
TP
TH
Thermostat
(Optional)
Therm
opile
Black
Black
St124c
Thermostat
wiring
1/11/00 djt
TP/TH
TP
TH



Drafthood Adapter
Harness
Remote Wall Switch or
ON/OFF Rocker Switch
TH
TP
TH
TP
Gas
Valve
ST943
Fig. 63 Draft Hood Adapter (FSDHAG) wiring. Used on