Brochure

153
www.centuryelectricmotor.com
Three Phase TEFC NEMA “C” Face General Purpose Motors
Three Phase - Squirrel Cage - No Base
3600 - 1800 & 1200 RPM - 1/4 thru 75 HP
Features:
• Ball Bearing 40˚C Ambient Keyed Shaft 60 HZ Reversible
Applications:
Designed for industrial and commercial pumps, speed reducers and other equipment that mounts directly on a NEMA “C” Face type motor.
Full Load Service Stock Insul. Cast “C”
HP
RPM
Volts
Amps
Factor
Frame
Number
Type
Enclosure
Class
Iron
Dim.
Notes
1/4 1725 208-230/460 1.2-1.1/.55 1.00 56C H157V1 TENV B 9.5 New!
1/3
3450
200-230/460
1.3-1.4/.7
1.15
56C
H288
TENV
B
9.2
1/3
1725/1425
200-230/460
1.3-1.2/.6
1.15
56C
H159L
TENV
B
10.2
6, New!
1/3
1725/1425
200-230/460
1.4-1.5/.75
1.15
56C
H061L
J
TEFC
B
11.1
6,48, New!
1/3
1140
200-230/460
1.8-1.6/.8
1.15
56C
H031
TENV
B
10.2
1/2 3450 200-230/460 1.9-1.8/.9 1.15 56C H473 TENV B 9.5
1/2
1725/1425
200-230/460
1.6-1.8/.9
1.15
56C
H062L
TEFC
B
11.6
6, New!
1/2
1725/1425
200-230/460
1.6-1.8/.9
1.15
56C
H256L
TENV
B
10.2
6, New!
3/4
3450
200-230/460
2.5-2.4/1.2
1.15
56C
H563
TENV
B
10.5
3/4
1725/1425
200-230/460
2.2-2.4/1.2
1.15
56C
H257
TENV
B
11.0
1,6,48
3/4 1725/1425 200-230/460 2.2-2.4/1.2 1.15 56C H257L TENV B 11.4 6, New!
3/4
1725/1425
200-230/460
2.5-2.4/1.2
1.15
56C
H063L
J
TEFC
B
11.7
6, New!
3/4
1140
200-230/460
4.0-4.0/2.0
1.15
56C
H035
TEFC
B
12.2
1
3450
200-230/460
3.2-3.0/1.5
1.15
56C
H633
TEFC
B
11.3
1
1730
230/460
2.8/1.4
1.15
143TC
TCF82026E
E+3(NP)
TEFC
F
13.2 New!
1
1725/1425
200-230/460
3.3-3.2/1.6
1.15
56C
H921L
TEFC
B
12.0
6, New!
1
1725/1425
200-230/460
3.3-3.2/1.6
1.15
143TC
H064L
J
TEFC
B
12.7
6,
48, New!
1
1140
230/460
3.4/1.7
1.15
145TC
TCF82051E
E+3(NP)
TEFC
F
13.2 New!
1
1/2
3470
230/460
3.8/1.9
1.15
143TC
TCF82002E
E+3(NP)
TEFC
F
13.2 New!
1
1/2
3450
200-230/460
4.5-4.2/2.1
1.15
56C
H751
TEFC
B
11.7
1
1/2
1730
230/460
4.2/2.1
1.15
145TC
TCF82027E
E+3(NP)
TEFC
F
13.2 New!
1
1/2
200-230/460
4.5-4.4/2.2
1.15
56C
H931L
TEFC
B
12.4
New!
1
1/2
1165
230/460
4.8/2.4
1.15
182TC
TCF82052E
E+3(NP)
TEFC
F
15.4 New!
2
3475
230/460
5.0/2.5
1.15
145TC
TCF82003E
E+3(NP)
TEFC
F
13.2 New!
2
3450
200-230/460
6.0-5.5/2.75
1.15
56C
H753
TEFC
B
12.2
2
3450
575
2.2
1.00
56C
H948
TEFC
B
12.6
1
2
1730
230/460
5.6/2.8
1.15
145TC
TCF82028E
E+3(NP)
TEFC
F
13.2 New!
2
1725/1425
200-230/460
6.0-5.8/2.9
1.15
56C
H703L
TEFC
B
13.2
6,
48, New!
2
1165
230/460
5.8/2.9
1.15
184TC
TCF82053E
E+3(NP)
TEFC
F
15.4 New!
Notes:
Continues on next page
1. Item to be discontinued when stock is depleted
6. 60/50 Hertz
48. 1.0 Service Factor at 50 Hz
Published efficiency on tri-voltage rated motors
applies at 230/460 volts. Performance at 200 or
208 volts may not be in accordance with
NEMA standards.
Shaft Dimensions
56C = 5/8” Keyed x 1-7/8”
56HC = 5/8” Keyed x 1-7/8”
143TC/145TC = 7/8” Keyed x 2-1/4”
182TC/184TC = 1-1/8” x 2-3/4”
213TC/215TC = 1-3/8” x 2-3/4”
H751
Motors specially designed, tested and warranted to
be Corona-Free for compatible inverter duty are
marked on this page with a J. See page 4 and 5
of this catalog for more Speed Engineered
®
motors
information.