Brochure


www.centuryelectricmotor.com
Century
®
Farm Duty Motors
Single Phase – Capacitor Start Totally-Enclosed Fan-Cooled
Rigid Base and Rigid Base with C-Face 1800 RPM – 1/3 thru 2 HP

• High Starting Torque 40°C Ambient • Ball Bearings
• Rigid Base 60 Hz Bearings Lubricated with Low Temperature Grease

Fans and blowers, feed lot conveyors, liquid manure spreaders, unloaders, compressors, storage bin conveyors.
Full Load Service Stock Insul. Overload “C”
HP RPM Volts Amps Factor Frame Number Enclosure Class Protector Rotation Dim. Notes
1⁄3
1725 115/230 5.2/2.6 1.25 56 C310 TENV B Manual RCC 11.1
1⁄3
1725 115/230 5.2/2.6 1.25 56 C310C TENV B Manual RCC 11.1
1⁄2
1725 115/230 7.2/3.6 1.25 56 C311 TEFC B Manual RCC 12.2
1⁄2
1725 115/230 7.2/3.6 1.25 56 C311C TEFC B Manual RCC 12.2
3⁄4
1725 230/115 5.2/10.4 1.15 56 C312 TEFC B Manual RCC 12.6
3⁄4
1725 230/115 5.2/10.4 1.15 56 C312C TEFC B Manual RCC 12.6
1 1725 230/115 6.0/12.0 1.15 56 C313 TEFC B Manual RCC 13.4
1 1725 230/115 6.0/12.0 1.15 56 C313C TEFC B Manual RCC 13.4
1
1⁄2
1725 230/115 7.5/15.0 1.15 56 C314 TEFC B Manual RCC 13.9 5
,
$
1
1⁄2
1725 230/115 7.5/15.0 1.15 56 C314C TEFC B Manual RCC 13.9 5
,
$
2 1725 230 9.0 1.15 56HZ C319 TEFC B Manual RCC 15.0 5
,
$

$EnergyEfficient$
5.
$
EnergyEfficienttwovaluecapacitorstartcapacitorrunmotor
Century
®
High Torque Farm Equipment Motors
Single Phase – Capacitor Start & Two Value Capacitor Designs
Rigid Base – 1800 & 1200 RPM 1 1/2 thru 10 HP

• Ball Bearings • 40°C Ambient Rigid Base
• Reversible • 60 Hz Energy Efficient $

Vacuum pumps, compressors, conveyors and feeders.
Full Load Service Stock Insulation Overload “C”
HP RPM Volts Amps Factor Frame Number Enclosure Class Protector Dim. Efficiency Notes
Totally-Enclosed Fan-Cooled
1
1⁄2
1745 230/115 7.5/15.0 1.15 145T K104 TEFC B Manual 15.0 5,
$
2 1750 115/230 24.0/12.0 1.00 182T K213 TEFC F Manual 15.7 72.5
2 1725 230/115 8.7/17.4 1.00 182TZ K119 TEFC B Manual 15.5 80.7 5
,
$
3 1750 230 16.0 1.00 184T K214 TEFC F Manual 15.7 78.5
5 1750 230 20.0 1.00 184T K215 TEFC F Manual 19.0 84.0 5
,
$
5 1750 230 23.0 1.00 213T K310 TEFC B Manual 17.6 81.0 5
,
$
7
1⁄2
1745 230 34.0 1.00 215T K311 TEFC B Manual 19.1 84.0 5
,
$
10 1750 230 38.0 1.00 215T K312 TEFC F Manual 19.1 87.5 5
,
$
Surge Replacement
Applications: Designed for replacement on “Surge” pumps.
5
1⁄2
1135 230 28.2 1.00 215T V308 ODP F Manual 17.8 79.9 5,214
,
$
Notes:
$EnergyEfficient$
5.
$
EnergyEfficienttwovaluecapacitorstart,capacitorrunmotor
214.F2Assembly
C312
K213