Brochure


www.centuryelectricmotor.com
Century
®
56-Frame Two-Speed Replacement Spa Motors
Dripproof – 60 HZ Single Phase Rigid Base – 6-1/2” Diameter – 3-1/2” Shaft Height

PSC on High Speed Cap Start/Cap Run on Low Speed 3/8-16 UNC-2A Threads Includes Slinger
E-Plus New Centurion Design 50˚C Ambient Four Thru Bolts on a 5.812 Bolt Circle
Status HP-SPL* RPM Volts Amps (A)** Frame Stock Insul. “C” Dim. Replaces Replaces Replaces Notes
Number Class Waterway # OEM # Stock #
NEW! 1.0 ~ .13 SPL 3450/1725 230 6.0/1.2 (A) 56Y B2232ê F 11.99 3720621 187692 B232 108
NEW! 2.0 ~ .25 SPL 3450/1725 230 7.4/1.4 (A) 56Y B2233ê F 12.24 3721021 187693 B233 108
2.5 ~ .31 SPL 3450/1725 230 11.6/3.0 (A) 56Y B2242ê F 13.24 108
NEW! 3.0 ~ .38 SPL 3450/1725 230 10.0/1.8 (A) 56Y B2234ê F 12.74 3721421 187694 B234 108
NEW! 4.0 ~ .50 SPL 3450/1725 230 12.0/3.0 56Y B2235ê F 13.49 3721621 187563 B235 108
5.0 ~ .63 SPL 3450/1725 230 16.4/4.8 56Y B236ê F 13.37 3722021 187098 108
4.0 SPL 3450 230 12.0 56Y B237 B 12.62 3711821 187624
5.0 SPL 3450 230 16.4 56Y B238 B 13.37 3712021 187970
Notes:
*HP-SPLmeansHorsepower–SpecialThereferencechartprovidedbelowliststhehorsepowerandhorsepowerAmpsat1.0servicefactorinrelationtothe
HP-SPLratings.
**(A)MaxLoadAmpRating–Asaguideline,at230V±10%voltage,donotloadmotorabovethisAmprating.Ampdrawdifferencesbetweenthepremium
efciencyE-PlusNewCenturiondesign(e.g.B2233)andtheslightlylessefcientdiscontinuedCenturiondesign(e.g.B233)isattributableinparttothead-
ditionofaruncapacitoronlowspeed.UseofAmpdatatodeterminethecorrectreplacementisnotrecommended.Instead,refertothechartforthecorrect
stocknumbertoreplaceeitheranoriginalWaterwaypumpmotororthenowdiscontinuedCenturionstockmotor.
108.Twospeedmotor
êMeetsCaliforniaEnergyCommissionApplianceRegulations2008PublicationNumberCEC-400-2006-002-REV1www.energy.ca.gov

       
1.0~.13
SPL
 2.0~.25
SPL
 3.0~.38
SPL
 4.0~.50
SPL
 5.0~.63
SPL
4.0
SPL
 5.0
SPL
1.0/.12 1.5/.19 2.0/.25 3.0/.38 4.0/.50 3.0 4.0
4.8/.8 6.4/1.2 8.8/1.6 12.0/3.0 16.4/4.8 12.0 16.4





Important:
1.
T
otal output (HP x service factor) of replacement motor
must equal or exceed motor being replaced.
2.
The pool motors on this page are
NOT equipped with a
Safety V
acuum Release System (SVRS). SVRS helps
prevent drowning due to body entrapment on underwater
drains. In some pool configurations, if a person’
s body
covers the drain, the person can be trapped by suction.
The SVRS turns off the pump if this occurs.
Depending on your pool configuration,
a SVRS may be required to meet local, state, and federal
requirements.
B232
B233
B234
B235
1.0 ~ .18 SPL
2.0 ~ .25 SPL
3.0 ~ .30 SPL
4.0 ~ .50 SPL
3450/1725
3450/1725
3450/1725
3450/1725
230
230
230
230
6.4/2.6 (A)
8.0/3.0 (A)
10.0/3.5 (A)
12.0/4.4
3720621
3721021
3721421
3721621
Disc. Stock
Number
HP-SPL* RPM Volts Amps (A)**
Replaces
Waterway#
Discontinued Centurion Stock Number Reference