Supplementary Document
www.certainteed.com http://blog.certainteed.com
CertainTeed Corporation
P.O. Box 860
Valley Forge, PA 19482
Professional: 800-233-8990
Consumer: 800-782-8777
© 05/10 CertainTeed Corporation
Code No. CTC-4810
ASK ABOUT ALL OF OUR OTHER CERTAINTEED
®
PRODUCTS AND SYSTEMS:
ROOFING • SIDING • TRIM • WINDOWS • DECKING • RAILING • FENCE
INSULATION • GYPSUM • CEILINGS •
FOUNDATIONS • PIPE
Characteristics, properties or performance of materials or systems manufactured by CertainTeed herein described are derived from data obtained under controlled test conditions.
CertainTeed makes no warranties, express or implied, as to their characteristics, properties or performance under any variations from such conditions in actual construction.
CertainTeed assumes no responsibility for the effects of structural movement.
NOTICE: The information in this document is subject to change without notice. CertainTeed assumes no responsibility for any errors that may inadvertently appear in this document.
Long Form Specifications
Classic Stab System
Section 09510 - Acoustical Ceilings
www.Certainteed.Com/CeilingS
PART 1 - GENERAL
1.1SectionIncludes
Provide metal suspension system for lay-in acoustical panel ceiling.
1.2 Related Sections
A.Section09120-CeilingSuspensionSystems
B.Section09250-GypsumBoard
C.Section09545-SpecialCeilingSurfaces
D.Section13020-IntegratedCeilings
E.Section13080-Sound,Vibration,andSeismicControl
F.Section15500-Heating,Ventilating,andAirConditioning
G.Section16500-Lighting
1.3References
A.AmericanSocietyforTestingandMaterials(ASTM)
1.C635-StandardSpecificationfortheManufacture,
Performance,andTestingofMetalSuspensionSystems
forAcousticalTileandLay-InPanelCeilings.
2.C636-StandardPracticeforInstallationofMetalCeiling
SuspensionSystemsforAcousticalTileandLay-InPanels.
3.E580-StandardPracticeforApplicationofCeiling
SuspensionSystemsforAcousticalTileandLay-InPanels
inAreasRequiringModerateSeismicRestraint.
B.Ceiling&InteriorSystemsConstructionAssociation(CISCA)
1.CeilingSystemsHandbook
2.GuidelinesforSeismicRestraintDirectHungSuspended
CeilingAssemblies
1.4 Submittals
A.Productdatasheetslistingdimensions,loadcarryingcapacity
and standards compliance.
B. Samples: 12 inch long samples of main runner and cross tee
with couplings.
1.5 Project Conditions
A.EnvironmentalRequirements:
1.Verifyweathertightnessofareatoreceivesuspension
system prior to installation.
2. Wet trades work to be thoroughly dry and complete prior to
suspension system installation.
3.Installationtobeginonlywhentemperatureandhumidity
conditions closely approximate interior conditions which will
exist when area is complete and occupied.
4.Heatingandairconditioningsystemstobeoperatingprior
to,during,andafterinstallation.
1.6Maintenance
Furnish additional material equal to _____ percent of ceiling area.
PART 2 - PRODUCTS
2.1Manufacturers
A.SuspensionSystems:
1. CertainTeed Ceilings Classic Stab System
2.2 Suspension System Components
A.MainRunners:
1.Manufacturedfrom[0.015][0.020]inchthickcorrosion-
resistant steel 15/16 inch wide by 1-1/2 inches high by
144incheslongwithfactorypunchedcrossteeslots,
hangerholes,andintegralbayonet-styleendcouplings.
Doubleweb[intermediate][heavy]dutynon-firerated
ceiling suspension system.
2. Capped with corrosion-resistant steel capping affixed to
15/16 inch flange.
3.Coatedwithfactory-appliedstandardcolorbaked-on
enamel paint finish.
4.Manufacturedwithfireexpansionreliefsonfire-rated
components.
B. Cross Tees:
1.Manufacturedfrom[0.012][0.015]inchthickcorrosion-
resistant steel 15/16 inch wide by 1-1/2 inches high by
[12][24][48][60][96]incheslongwithfactorypunched
cross tee slots and hanger holes.
2. Capped identical to main runners.
3.Finishedidenticaltomainrunners.
4.Manufacturedwithfactoryattachedstainlesssteelcouplings
on component ends.
5.Manufacturedwithfireexpansionreliefsonfirerated
components.
C. Perimeter Treatment Components:
1.Type:[angle,shadow-line,channel]
2.Profile:AsselectedbytheArchitect
D.AttachmentDevices:
SizeforfivetimesdesignloadindicatedinASTMC635,Table
1,DirectHungunlessotherwiseindicated.
E.WireforHangersandTies:
Class1zinccoating,softtemper,prestretched,withayield
stressloadofatleastthreetimesdesignload,butnotless
than 12 gage.
F.Accessories
PART 3 - EXECUTION
3.1Examination
Examine area receiving suspension system to identify conditions
whichwilladverselyaffectinstallation.Donotbegininstallation
until adverse conditions have been remedied.
3.2Installation
A.Installtheceilingsysteminaccordancewiththefollowing:
1.Manufacturer’sprintedinstructions
2.ASTMC636,E580
3.Ceilings&InteriorSystemsConstructionAssociation(CISCA)
recommendations
4.Applicablelocalcoderequirements
5.Approvedshopdrawings
B.Installsuspensionsystemrequiringseismicrestraintin
compliancewithASTME580,CISCArecommendationsand
with the authorities having jurisdiction.
C.MainRunners:Installed[12][24][48][60][96]incheson
center,bydirectsuspensionfromexistingstructure,withnot
lessthan12gagesteelhangerwiresspaced48incheson
centeralongmainrunnerlength.Wraphangerwirestightly3
full turns at each end.
D.CrossTees:
1.Installedperpendiculartomainrunners_____incheson
center to form _____ by _____ inch modules.
2.Installedperpendiculartomoduleformingcrosstees_____
inches on center to form _____ by _____ inch modules.
3.Installedadjacenttoeachunsupportedsideofrecessed
fixtures.
E.[Angle][ShadowLine]Moldings:Installedon
verticalsurfaces,intersectingsuspension
components,byappropriatemethodin
accordance with industry-accepted practice.
F.AdditionalHangerWires:Wrappedtightly3fullturnsto
structure and component at locations where imposed loads
couldcausedeflectionexceeding1/360span.
3.3AdjustmentsandCleaning
A.Removedamagedcomponents,replacewithundamaged
components. Clean with non-solvent based non-abrasive
commercial cleaning solution.