Supplementary Document

www.certainteed.com http://blog.certainteed.com
CertainTeed Corporation
P.O. Box 860
Valley Forge, PA 19482
Professional: 800-233-8990
Consumer: 800-782-8777
© 05/10 CertainTeed Corporation
Code No. CTC-4810
ASK ABOUT ALL OF OUR OTHER CERTAINTEED
®
PRODUCTS AND SYSTEMS:
ROOFING SIDING TRIM WINDOWS DECKING RAILING FENCE
INSULATION GYPSUM CEILINGS
FOUNDATIONS PIPE
Characteristics, properties or performance of materials or systems manufactured by CertainTeed herein described are derived from data obtained under controlled test conditions.
CertainTeed makes no warranties, express or implied, as to their characteristics, properties or performance under any variations from such conditions in actual construction.
CertainTeed assumes no responsibility for the effects of structural movement.
NOTICE: The information in this document is subject to change without notice. CertainTeed assumes no responsibility for any errors that may inadvertently appear in this document.
Long Form Specifications
Classic Stab System
Section 09510 - Acoustical Ceilings
www.Certainteed.Com/CeilingS
PART 1 - GENERAL
1.1SectionIncludes
Provide metal suspension system for lay-in acoustical panel ceiling.
1.2 Related Sections
A.Section09120-CeilingSuspensionSystems
B.Section09250-GypsumBoard
C.Section09545-SpecialCeilingSurfaces
D.Section13020-IntegratedCeilings
E.Section13080-Sound,Vibration,andSeismicControl
F.Section15500-Heating,Ventilating,andAirConditioning
G.Section16500-Lighting
1.3References
A.AmericanSocietyforTestingandMaterials(ASTM)
1.C635-StandardSpecificationfortheManufacture,
Performance,andTestingofMetalSuspensionSystems
forAcousticalTileandLay-InPanelCeilings.
2.C636-StandardPracticeforInstallationofMetalCeiling
SuspensionSystemsforAcousticalTileandLay-InPanels.
3.E580-StandardPracticeforApplicationofCeiling
SuspensionSystemsforAcousticalTileandLay-InPanels
inAreasRequiringModerateSeismicRestraint.
B.Ceiling&InteriorSystemsConstructionAssociation(CISCA)
1.CeilingSystemsHandbook
2.GuidelinesforSeismicRestraintDirectHungSuspended
CeilingAssemblies
1.4 Submittals
A.Productdatasheetslistingdimensions,loadcarryingcapacity
and standards compliance.
B. Samples: 12 inch long samples of main runner and cross tee
with couplings.
1.5 Project Conditions
A.EnvironmentalRequirements:
1.Verifyweathertightnessofareatoreceivesuspension
system prior to installation.
2. Wet trades work to be thoroughly dry and complete prior to
suspension system installation.
3.Installationtobeginonlywhentemperatureandhumidity
conditions closely approximate interior conditions which will
exist when area is complete and occupied.
4.Heatingandairconditioningsystemstobeoperatingprior
to,during,andafterinstallation.
1.6Maintenance
Furnish additional material equal to _____ percent of ceiling area.
PART 2 - PRODUCTS
2.1Manufacturers
A.SuspensionSystems:
1. CertainTeed Ceilings Classic Stab System
2.2 Suspension System Components
A.MainRunners:
1.Manufacturedfrom[0.015][0.020]inchthickcorrosion-
resistant steel 15/16 inch wide by 1-1/2 inches high by
144incheslongwithfactorypunchedcrossteeslots,
hangerholes,andintegralbayonet-styleendcouplings.
Doubleweb[intermediate][heavy]dutynon-firerated
ceiling suspension system.
2. Capped with corrosion-resistant steel capping affixed to
15/16 inch flange.
3.Coatedwithfactory-appliedstandardcolorbaked-on
enamel paint finish.
4.Manufacturedwithfireexpansionreliefsonfire-rated
components.
B. Cross Tees:
1.Manufacturedfrom[0.012][0.015]inchthickcorrosion-
resistant steel 15/16 inch wide by 1-1/2 inches high by
[12][24][48][60][96]incheslongwithfactorypunched
cross tee slots and hanger holes.
2. Capped identical to main runners.
3.Finishedidenticaltomainrunners.
4.Manufacturedwithfactoryattachedstainlesssteelcouplings
on component ends.
5.Manufacturedwithfireexpansionreliefsonfirerated
components.
C. Perimeter Treatment Components:
1.Type:[angle,shadow-line,channel]
2.Profile:AsselectedbytheArchitect
D.AttachmentDevices:
SizeforfivetimesdesignloadindicatedinASTMC635,Table
1,DirectHungunlessotherwiseindicated.
E.WireforHangersandTies:
Class1zinccoating,softtemper,prestretched,withayield
stressloadofatleastthreetimesdesignload,butnotless
than 12 gage.
F.Accessories
PART 3 - EXECUTION
3.1Examination
Examine area receiving suspension system to identify conditions
whichwilladverselyaffectinstallation.Donotbegininstallation
until adverse conditions have been remedied.
3.2Installation
A.Installtheceilingsysteminaccordancewiththefollowing:
1.Manufacturer’sprintedinstructions
2.ASTMC636,E580
3.Ceilings&InteriorSystemsConstructionAssociation(CISCA)
recommendations
4.Applicablelocalcoderequirements
5.Approvedshopdrawings
B.Installsuspensionsystemrequiringseismicrestraintin
compliancewithASTME580,CISCArecommendationsand
with the authorities having jurisdiction.
C.MainRunners:Installed[12][24][48][60][96]incheson
center,bydirectsuspensionfromexistingstructure,withnot
lessthan12gagesteelhangerwiresspaced48incheson
centeralongmainrunnerlength.Wraphangerwirestightly3
full turns at each end.
D.CrossTees:
1.Installedperpendiculartomainrunners_____incheson
center to form _____ by _____ inch modules.
2.Installedperpendiculartomoduleformingcrosstees_____
inches on center to form _____ by _____ inch modules.
3.Installedadjacenttoeachunsupportedsideofrecessed
fixtures.
E.[Angle][ShadowLine]Moldings:Installedon
verticalsurfaces,intersectingsuspension
components,byappropriatemethodin
accordance with industry-accepted practice.
F.AdditionalHangerWires:Wrappedtightly3fullturnsto
structure and component at locations where imposed loads
couldcausedeflectionexceeding1/360span.
3.3AdjustmentsandCleaning
A.Removedamagedcomponents,replacewithundamaged
components. Clean with non-solvent based non-abrasive
commercial cleaning solution.