User's Manual

5
32A 40A 48A 80A
CIRCUIT
REQUIREMENTS
40 Amp
2 pole breaker
50 Amp
2 pole breaker
60 Amp
2 pole breaker
100 Amp
2 pole breaker
RECOMMEND
WIRING
#8AWG or
larger gauge
copper
wires for the
conductors
(NEC 625.17(A)
(2)
#6AWG or
larger gauge
copper
wires for the
conductors
(NEC 625.17(A)
(2)
#4AWG or
larger gauge
copper
wires for the
conductors
(NEC 625.17(A)
(2)
#2 or 3AWG
or larger
gauge copper
wires for the
conductors
(NEC 625.17(A)
(2)
#10AWG
Green or bare
copper for
the ground
conductor (no
NEU)
#10AWG
Green or bare
copper for
the ground
conductor (no
NEUTRAL is
used)
#8AWG Green
or bare copper
for the ground
conductor (no
NEU)
#6AWG Green
or bare copper
for the ground
conductor (no
NEU)
WARNING
Do not continue this installation until the circuit breaker is turned o.
WIRING AND CIRCUIT REQUIREMENTS
For additional specications, refer to the Specications section.
Installation
Fully read and understand the directions before installation. Refer to impoant safety
information at the end of this document.
This section describes installing the JuiceBox Pro onto a wall mount. If installing onto a
JuiceStand, refer to the JuiceStand Manual.
1. Turn o the circuit breaker to the NEMA 14-50 outlet, NEMA 6-50 outlet, or hardwired
electrical connection.
2. Use a stud sensor to determine an appropriate mounting location, then use the 2 screws
to secure the wall bracket.