Inc. Precision Oscillator Specification Sheet

C&H Technologies, Inc. 445 Round Rock West Drive Round Rock, TX 78681-5012
(512) 733-2621
FAX (512) 733-2629 www.chtech.com
Outputs:
Front Panel
M-Module Trig A
M-Module Trig B
Switch Controls:
Divide-by-N Value (3 to 16383)
Clock Out Select
- Square Wave Output (N ÷ 2)
- Divide-By-2
- No divide (10MHz output)
- Divide-By-N
M-Trigger A/B Output Enable
Front Panel Output Enable
Front Panel Output Impedance
Front Panel Connector: SMA
Temperature:
Operating: 0°C to 50°C
Storage: -40°C to 70°C
Power:
+5V (during warm-up) 0.9 A
+5V (after warm-up) 0.65 A
CPCI/PXI Compliance
Complies with PCI spec. 2.0 R3.0
and PCI spec 2.2
5V and 3.3V signaling voltage (VIO)
supported
5V only power supply
33MHz PCI data bus
Five trigger lines compliant with PXI
Specification 2.1
Form Factor: Size 3U
Applications
Frequency or Time Reference
M-Module Triggering
Synchronization of data
acquisition hardware
Ordering Information
Part Number 11030260-0001
Additional Information
User Manuals can be found on our
website at www.chtech.com.
Specifications:
Ovenized Oscillator:
Nominal Frequency: 10MHz
Stability (Freq. vs. Temp) ±0.01ppm
Aging (Freq. vs. Time)
1
st
year ±0.1ppm
10 years ±1.0ppm
Cal. (Freq. vs. Control) ±1.0ppm
Warm Up (Freq. Ref. to 1 hr.)
5 minutes ±0.1ppm
30 minutes ±0.01ppm
Front panel accessible calibration
25-turn potentiometer provided for
10 year adjustability.
Pulse Output: (front panel)
High, I
OH
= -24mA 3.76V min.
Low, I
OL
= 24mA 0.44V max.
Source/Sink ±50mA
Rise/Fall (0.8 to 2.0V) 1.5ns
Impedance (selectable) 3 or 50Ω
Pulse Width: 100ns*
* Pulse width is 50% of period when
“Square Wave Output” or “No divide”
output is selected.
PX467S
Precision
Oscillator
The PX467S is a precision oscillator
source that provides a highly
accurate and stable clock reference
that can be used as a frequency or
time reference. Using selectable
switches, the output of the on-board
ovenized oscillator can be output as
is or divided by any value from 2 to
16383. The resulting output can be
directed to a front SMA connector
and/or to selected PXI triggers. The
output can be a 100ns pulse or a
square wave.
This unit also features a position for
adding one single wide M Module.