Chapter 7. Configuration Complete
707112-001
What to do if Your Configuration Will Not Boot
One possible cause for this type of problem would be the result of removing one of the cards
prior to the IML.
A procedure to correct the problem is as follows.
Press the IML button on the front panel, to initiate a fresh IML. When the unit reaches IML
state 500, a pause of about 5-10 seconds will occur. During this pause press the <Config>
button on the front panel. This will cause the SCON-3074 to boot on the factory default
configuration, based on the actual hardware installed in the unit. You should see the
Configuration indicator on the front panel light when the IML continues beyond state 500,
and remain on until the IML is complete. When fully booted, the SCON-3074 will display the
word ‘CONFIGURATION’ on the front panel LCD.
Connect to the SCON-3074 with your Telnet client. You have a couple of choices as you enter
the utility. If you select to use the “Default” data source, you can configure the SCON-3074
from scratch, the same as when you first received it. You can also select “Drive C” as the
source, which will bring up the last saved configuration (the one with the problem) and allow
you to attempt to change the configuration to one that will work.