User's Manual

13
Problem Cause(s) Solution(s)
Troubleshooting
Flowing water supply line pres-
sure measured at the glass-
washer exceeds 95 psi [655
kPa].
Defective solenoid valve(s).
DefectiveAUTO-FILLswitch.
Rinse water pressure too high
Chemical container(s) are
empty.
Chemical supply line(s) are
clogged.
Chemical supply and/or pump
tube(s) are broken.
Nopowertochemicaldispens-
ing pump(s).
Dispensing pump is defective.
Chemical pumps out of
adjustment
Waterowsintoglasswasher
whenON/OFFswitchisin
the OFF position.
Chemical(s)arenotowinginto
the glasswasher.
Reduceowingwaterpressure
measured at the glasswasher
below 95 psi [655 kPa].
Authorizedserviceagentmay
rebuild or replace the solenoid
valve(s).
Incomingwaterpressuremustbe
5PSI/35kPaonpressuregauge
located on right-side of glasswasher
lower compartment
Rellthecontainer(s).
Remove the supply line(s) from the
chemicalcontainersandushwith
warm water.
Replace supply line(s) and/or pump
tube(s).
Authorizedserviceagentmustinspect
and repair
Chemical supplier must adjust
chemical pumps.
Authorizedserviceagentmayreplace
chemical dispensing pump.
Service agent replace the switch.