9.2 MISSING DEFINITION IN IRRIGATION PROGRAM
will appear
if irrigation
duration is set at
zero (0:00)
(see NOTE: in Section 8.5). In this
case, the valve cannot be opened for automatic
or manual operation via the controller.
9.3 PROGRAMMING ERROR
In the cyclical program (see section 8.4) if the
irrigation duration programmed is equal to or
longer than the irrigation cycle, the word
will appear.
To cancel the error, press
or to increase
the irrigation cycle.
10. HELPFUL HINTS AND ADDITIONAL INFORMATION
1. Manual runs can be initiated at any time when current time is displayed by
pressing the manual button once. The valve will operate one time for the length
of time programmed and then proceed back to the normal programming.
2. All DIG controllers can be programmed first and installed at a later date. No
water pressure is required.
3. Always make sure that the battery compartment is clean and dry. If water should
get on the battery, immediately remove and wipe clean.
4. We strongly recommend brand name alkaline batteries. Rechargeable batteries
are not recommended.
5 Under normal usage, batteries (alkaline) will last for a minimum of 1 year,
maximum of 2 years.
6. It is good operating practice to replace old batteries with new ones at the start of
the irrigation season.
7. The valve actuator can be opened and closed manually by turning the external
bleed screw to the left and right.