Instruction manual

7. INSTALLATION OF VALVE ADAPTER WITH CONTROLLER
Operating pressure: 25-125 PSI
1. Shut off main water supply.
2. Remove the manual stem from the existing valve and temporarily remove the
anti-siphon cap (see A).
3. Replace any existing worn washers with the new ones provided.
4. Install the actuator with the controller into the manual anti-siphon valve body by
turning actuator clockwise. Tighten firmly, but do not over tighten (see B).
5. Turn on main water supply.
6. Program the controller, or if the controller is programmed, make sure the
current time, a duration, days of operation and start time are displayed.
7. Press
to test the controller. A click will be heard indicating the valve is
open ( The
and symbols will appear on the lower right side).
8. Turn flow control knob clockwise to decrease flow, counter-clockwise to
increase flow.
8
Manual Stem
Flow control knob
Anti-Siphon Cap
Valve
Body
A B C