Product Brochure

19
ENGLISH 100307
MAINTENANCE AND STORAGE
Storage
The generator should be started at least once every
14 days and allowed to run for at least 20 minutes.
For longer term storage, please follow these guidelines.
Generator Storage
1. Add a properly formulated fuel stabilizer to the gas
tank.
2. Be sure all appliances are disconnected from the
generator.
3. Run the generator for a few minutes so the treated
fuel cycles through the fuel system and carburetor.
4. Turn the gas fuel valve to the Off position.
5. Let the generator run until fuel starvation has
stopped the engine. This usually takes a few minutes.
6. Press the engine switch to the “OFF” position.
7. The generator needs to cool completely before
cleaning and storage.
8. Remove the spark plug cap, then pull the recoil grip
3 times to drain the gasoline from the carburetor
jets.
9. Remove the spark plug and pour about a tablespoon
of oil into the cylinder. Crank the engine slowly to
distribute the oil and lubricate the cylinder.
10. Reattach the spark plug.
11. Clean the generator according to the maintenance
section.
12. Store the unit in a clean, dry place out of direct
sunlight.
Generator exhaust contains odorless and colorless
carbon monoxide gas.
To avoid accidental or unintended ignition of your
generator during periods of storage, the following
precautions should be followed:
When storing the generator for short or extended
periods of time make sure that the engine switch
and the fuel valve are set in the OFF position.
DANGER