Full Product Manual

100424 - 27 TON FULL BEAM LOG SPLITTER
STORAGE
21
7. Turn the fuel valve to the ON position, and start
the engine. Purge the air from the system by extending
and retracting the wedge several times until the motion is
smooth.
8. Check the hydraulic oil level using the sight glass.
Add 1 - 1.5 gal (3.8 – 5.7 L) of hydraulic oil, so the
oil level is visible in the sight glass (C).
9. Dispose of used oil at approved recycling locations in
accordance with Federal, State, Local or Provincial
regulations.
B
C
A
! WARNING
Always shut off the engine, disconnect the spark plug,
and relieve system pressure before cleaning, adjusting,
or repairing the splitter. Relieve system pressure by moving
split control lever back and forth several times
"
NOTICE
Refer to Specifications for a list of compatible replacement
filters or call Champion Power Equipment at
1-877-338-0999 to order a replacement OEM lter.
Maintenance Schedule
Follow the service intervals indicated in the following
maintenance schedule.
Service your log splitter more frequently when operating in
adverse conditions.
Contact our Technical Support Team at 1-877-338-0999 to
locate the nearest CPE certified service dealer for your log
splitter or engine maintenance needs.
EVERY 8 HOURS OR DAILY
# Check engine and hydraulic oil levels
# Clean around air intake and muffler
FIRST 5 HOURS
# Change oil
EVERY 50 HOURS OR EVERY SEASON
# Clean air filter
# Change oil if operating under heavy load or in hot
environments
EVERY 100 HOURS OR EVERY SEASON
# Change oil
# Clean/adjust spark plug
# Check/adjust valve clearance*
# Clean spark arrestor
# Clean fuel tank and filter*
# Change hydraulic oil
# Change hydraulic oil filter
EVERY 250 HOURS
# Clean combustion chamber*
EVERY YEAR
# Inspect wheel bearings and repack bearing grease as
needed.
EVERY 3 YEARS
# Replace fuel line*
* To be performed by knowledgeable, experienced owners or CPE certied
service centers.
STORAGE
Refer to the Maintenance section for proper cleaning
instructions.
Log Splitter Storage
1. The log splitter needs to be cool for at least 5 minutes
before storing.
2. Clean the log splitter before storage according to the
Maintenance section.
3. Retract the wedge to protect the rod from corrosion.
4. Wipe the beam and wedge with an oily rag to prevent rust
and corrosion.
Engine Stored for Less than 30 Days
1. Allow the engine to cool completely before storage.
2. Clean engine according to the Maintenance section.