Full Product Manual

100519 - 6250W OPEN FRAME INVERTER
ASSEMBLY
16
Install the Handle
1. Place the handle (F) over the mounting channel on the
frame.
2. Secure the handle to the frame using the four flange
bolts (G).
F
G
Add Engine Oil
CAUTION
DO NOT attempt to crank or start the engine before it has
been properly filled with the recommended type and amount
of oil. Damage to the generator as a result of failing to follow
these instructions will void your warranty.
NOTICE
The generator rotor has a sealed, pre-lubricated ball bearing
that requires no additional lubrication for the life of the bearing.
NOTICE
The recommended oil type for typical use is 10W-30
automotive oil.
If running generator in extreme temperatures, refer to the
following chart for recommended oil type.
-20 0 20 40 60
Ambient temperature
Recommended Engine Oil Type
80 100 120
-28.9
°F
°C -17.8 -6.7 4.4 15.6 26.7 37.8 48.9
10W-30
5W-30 Full Synthetic
10W-405W-30
1. Place the generator on a flat, level surface.
2. Remove oil fill cap/dipstick to add oil.
3. Using a funnel, add up to 37.2 fl. oz. (1.2 qt.) of oil
(not included) and replace oil fill cap/dipstick. DO NOT
OVERFILL.
4. Check engine oil level at every use and add as needed.
MAX
NOTICE
Once oil has been added, a visual check should show oil
about 1-2 threads from running out of the fill hole.
When using the dipstick to check oil level, DO NOT screw in
the dipstick while checking.
NOTICE
Check oil level often during the break-in period. Refer to the
Maintenance section for recommended service intervals.
CAUTION
This engine is equipped with a low oil shut-off and will stop
when the oil level in the crankcase falls below the threshold
level.