Full Product Manual

100519 - 6250W OPEN FRAME INVERTER
MAINTENANCE
25
Cleaning the Spark Arrestor
1. Allow the engine to cool completely before servicing the
spark arrestor.
2. Remove the two or three screws (varies by model) holding
the cover plate which retains the spark arrestor to the
mufer.
3. Remove the spark arrestor screen.
4. Carefully remove the carbon deposits from the spark
arrestor screen with a wire brush.
* See your model’s parts list for specified type of spark arrestor.
5. Replace the spark arrestor if it is damaged.
6. Position the spark arrestor on the muffler and attach with
the screws removed in step 2.
CAUTION
Failure to clean the spark arrestor will result in degraded
engine performance.
NOTICE
Federal and local laws and administrative requirements
indicate when and where spark arrestors are required.
When ordered, spark arrestors are required for operation
of this generator in National Forest lands. In California,
this generator must not be used on any forest-covered
land, brush-covered land, or grass-covered land unless the
engine is equipped with a spark arrestor.
Adjusting the Governor
WARNING
Tampering with the factory set governor will void your
warranty.
The air-fuel mixture is not adjustable. Tampering with
the governor can damage your generator and your
electrical devices and will void your warranty. Contact our
DELETE "NATIONAL FOREST" NOTICE IF CANADA ONLY ITEM
Technical Support Team at 1-877-338-0999 for all other
service and/or adjustment needs.
Maintenance Schedule
Follow the service intervals indicated in the following
maintenance schedule.
Service your generator more frequently when operating in
adverse conditions.
Contact our Technical Support Team at 1-877-338-0999
to locate the nearest CPE certified service dealer for your
generator or engine maintenance needs.
EVERY 8 HOURS OR PRIOR TO EACH USE
Check oil level
Clean around air intake and muffler
FIRST 5 HOURS (BREAK IN)
Change oil
EVERY 50 HOURS OR ANNUALLY
Clean air filter
Change oil if operating under heavy load or in hot
environments
EVERY 100 HOURS OR ANNUALLY
Change oil
Clean/adjust spark plug
Clean spark arrestor
Clean fuel valve filter*
EVERY 250 HOURS
Clean combustion chamber*
Check/adjust valve clearance*
EVERY 3 YEARS
Replace fuel line*
* To be performed by knowledgeable, experienced owners or CPE certified
service centers.