Full Product Manual

100565 - 2000W PORTABLE INVERTER GENERATOR
STORAGE
24
FIRST 5 HOURS
# Change oil
EVERY 50 HOURS OR EVERY SEASON
# Clean air filter
# Change oil if operating under heavy load or in hot
environments
EVERY 100 HOURS OR EVERY SEASON
# Change oil
# Clean/adjust spark plug
# Check/adjust valve clearance*
# Clean spark arrestor
# Clean fuel tank and filter*
EVERY 250 HOURS
# Clean combustion chamber*
EVERY 3 YEARS
# Replace fuel line*
* To be performed by knowledgeable, experienced owners or CPE certied
service centers.
STORAGE
! DANGER
Gasoline and gasoline vapors are highly flammable and
extremely explosive.
Fire or explosion can cause severe burns or death. Only
fill or drain fuel outdoors in a well-ventilated area. DO NOT
pump gasoline directly into the generator. Use an approved
container to transfer the fuel to the generator. Never use
a gasoline container, gasoline tank, or any other fuel item
that is damaged or appears damaged. DO NOT overll the
gasoline tank. Always keep fuel away from sparks, open
flames, pilot lights, heat and other sources of ignition.
DO NOT light or smoke cigarettes.
Short Term Storage (up to 1 year)
Gasoline in the gasoline tank has a maximum shelf life of up to
1 year with the addition of properly formulated fuel stabilizers
and if stored in a cool, dry place. Gasoline in the carburetor,
however, may gum up and clog the carburetor if it isn’t used or
drained within 2-4 weeks.
1. Be sure all appliances are disconnected from the generator.
2. Add a properly formulated fuel stabilizer to the gasoline
tank.
3. Start engine by following directions in the “Starting the
Engine” section.
4. Run the generator for 10 minutes so the treated gasoline
cycles through the fuel system and carburetor.
5. Stop engine by turning the EZ Start dial to the RUN OUT OF
FUEL position.
6. After fuel has run out and the engine has stopped, allow
the engine to cool.
7. Remove maintenance cover.
8. Remove the spark plug and pour about a tablespoon of oil
into the cylinder.
9. SLOWLY pull the recoil to rotate the engine to distribute
and lubricate the cylinder.
10. Re-install the spark plug and spark plug wire.
11. Re-install the maintenance cover.
12. Clean the generator according to Cleaning the Generator.
13. Store the generator in a cool, dry place out of direct
sunlight.
Long Term Storage (more than 1 year)
For storage over 1 year, the gasoline tank and carburetor must
be completely drained of gasoline.
1. Be sure all appliances are disconnected from generator.
2. Place inverter on blocks to allow appropriate gasoline
container or pan to slide under inverter.
3. Remove the maintenance cover.
4. Turn the EZ Start dial to the RUN position.
5. Using a Phillips screwdriver, rotate drain screw
counterclockwise (3) full turns. Gasoline will drain through
clear tubing out underneath the inverter. Make sure
draining gasoline empties into an appropriate container.