Operating Guide

15
100742 - 2 IN. (5 CM) SEMI-TRASH PUMP
OPERATION
EMPTY FULL
4. Screw on the gasoline cap and wipe away any spilled fuel.
CAUTION
Use regular unleaded gasoline with a minimum octane rating
of 87 and an ethanol content of less than 10% by volume.
DO NOT light cigarettes or smoke when filling the tank.
DO NOT mix oil and gasoline.
Fill tank to approximately ¼ in. (6.4 mm) below the top of the
tank to allow for gasoline expansion.
DO NOT pump gasoline directly into the water pump at the
pump. Use an approved container to transfer the gasoline to
the water pump.
DO NOT fill tank indoors.
DO NOT fill tank when the engine is running or hot.
DO NOT overfill the tank.
WARNING
Pouring gasoline too fast through the fuel screen may result in
blow back of gasoline at the operator while filling.
NOTICE
Our engines work well with 10% or less ethanol blend
gasoline. When using ethanol-gasoline blends there are some
issues worth noting:
Ethanol-gasoline blends can absorb more water than
gasoline alone.
These blends can eventually separate, leaving water or a
watery goo in the tank, fuel valve and carburetor.
With gravity-fed supplies, the compromised gasoline can
be drawn into the carburetor and cause damage to the
engine and/or potential hazards.
There are only a few suppliers of fuel stabilizer that are
formulated to work with ethanol-gasoline blends.
Any damages or hazards caused by using improper
gasoline, improperly stored gasoline, and/or improperly
formulated stabilizers, are not covered by manufacturer’s
warranty.
It is advisable to always shut off the gasoline supply, run the
engine to starvation and drain the tank when the equipment is
not in use for more than 30 days.
OPERATION
Water Pump Location
DANGER
Water pump engine exhaust contains carbon monoxide,
a colorless, odorless, poison gas. Breathing carbon monoxide
will cause nausea, dizziness, fainting or death.
If you start to feel dizzy or weak, get to fresh air immediately.
OPERATE THE WATER PUMP OUTDOORS ONLY IN A WELL
VENTILATED AREA AND POINT EXHAUST AWAY.
DO NOT operate the water pump inside any building, including
garages, basements, crawlspaces and sheds, enclosure
or compartment, including the storage compartment of a
recreational vehicle.
DO NOT allow exhaust fumes to enter a confined area through
windows, doors, vents or other openings.