Use and Care Guide

19
100743 - 3 IN. (7.5 CM) SEMI-TRASH PUMP
OPERATION
10. Tighten each clamp to 7.4±1.5 lbf-ft (12 Nm) with a 13mm
wrench. If you do not have a torque wrench, hand tight then
¼ turn past full tight.
11. Test connection is tight by twisting coupler in the hose to
make sure it doesn’t turn. If coupling turns, then tighten
clamps further until coupling won’t turn.
12. Wrap the green inlet clockwise with the Teflon
®
tape provided
with 4 complete wraps.
13. Thread the fitting over the tape and hand tighten. If you have
channel locks large enough, you can give it a ¼ turn past
hand tight.
14. Attach the cam lock coupler to the fitting.
15. Lock in place with the cam levers.
NOTICE
If the cam levers do not clamp down completely, rotate and
align the clamp bolts so you have clearance for the cam levers
to lock. See step 9 earlier.
16. Locate the following: filter (E) and 80-85 marked hose
clamp (F).
E
F
17. Snap the filter pieces together.