OPERATOR'S MANUAL MODEL #200959 2000W Dual Fuel Inverter Generator REGISTER YOUR PRODUCT ONLINE at championpowerequipment.com or visit championpowerequipment.com SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do so could result in serious injury. This manual should remain with the product.
CARBON MONOXIDE SAFETY: THE BIG PICTURE As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, oderless threat.
Table of Contents 200959 - 2000W Dual Fuel Inverter Generator TABLE OF CONTENTS Storage................................................ ......... 26 Short Term Storage (up to 30 days).............................. 27 Introduction.................................................... 4 Mid Term Storage (30 days – 1 year)............................ 27 Safety Definitions........................................... 4 Long Term Storage (more than 1 year)...........................
Introduction 200959 - 2000W Dual Fuel Inverter Generator INTRODUCTION SAFETY DEFINITIONS Congratulations on your purchase of a Champion Power Equipment (CPE) product. CPE designs, builds, and supports all of our products to strict specifications and guidelines. With proper product knowledge, safe use, and regular maintenance, this product should bring years of satisfying service. The purpose of safety symbols is to attract your attention to possible dangers.
Important Safety Instructions 200959 - 2000W Dual Fuel Inverter Generator IMPORTANT SAFETY INSTRUCTIONS DANGER Operate equipment with guards in place. WARNING Rotating parts can entangle hands, feet, hair, clothing and/or accessories. Traumatic amputation or severe laceration can result. Cancer and Reproductive Harm – www.P65Warnings.ca.gov DANGER Keep hands and feet away from rotating parts. Generator exhaust contains carbon monoxide, a colorless, odorless, poisonous gas.
Important Safety Instructions 200959 - 2000W Dual Fuel Inverter Generator CAUTION WARNING Spark from removed spark plug wire can result in fire or electrical shock. Start the generator and allow the engine to stabilize before connecting electrical loads. When servicing the generator: Connect electrical equipment in the off position, and then turn them on for operation. Disconnect the spark plug wire and place it where it cannot contact the plug or any other metal object.
Important Safety Instructions 200959 - 2000W Dual Fuel Inverter Generator Fuel Safety When adding or removing gasoline: DO NOT light or smoke cigarettes. DANGER GASOLINE, GASOLINE VAPORS AND PROPANE (LPG) ARE HIGHLY FLAMMABLE AND EXPLOSIVE. Turn the generator off and let it cool for at least two minutes before removing the gasoline cap. Loosen the cap slowly to relieve pressure in the tank. Fire or explosion can cause severe burns or death.
Important Safety Instructions 200959 - 2000W Dual Fuel Inverter Generator Safety and Dataplate Labels These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement. C D A B Top Side Muffler LABEL DESCRIPTION 1385-L-SF-C DANGER PELIGRO A El uso de un generador en interiores PUEDE MATARLO EN MINUTOS. El escape del generador contiene monóxido de carbono.
Important Safety Instructions 200959 - 2000W Dual Fuel Inverter Generator Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product. SYMBOL MEANING Read Operator’s Manual. To reduce the risk of injury, user must read and understand operator’s manual before using this product. Clearance. Keep all objects at least 5 feet (1.5m) from generator.
Important Safety Instructions 200959 - 2000W Dual Fuel Inverter Generator Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product. SYMBOL MEANING SYMBOL MEANING Engine Run: Gasoline Parallel Connection(s) Engine Run: Propane Neutral Floating. Neutral circuit IS NOT electrically connected to the frame/ ground of the generator.
Important Safety Instructions 200959 - 2000W Dual Fuel Inverter Generator Quickstart Label Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product. 10W-30 4 6 5 7 1 2 3 23 20 -L -OP-A 3 2 1 Starting the Engine Stopping the Engine 1. Turn off and unplug all connected electrical loads.
Controls and Features 200959 - 2000W Dual Fuel Inverter Generator CONTROLS AND FEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator 1 5 4 6 3 2 7 8 1. Carrying Handle – Used to lift or carry the unit. 2. Recoil Starter – Used to manually start the engine. 5. Fuel Lever Vent – Turn this valve to the “ON” position to supply air to the tank. 3.
Controls and Features 200959 - 2000W Dual Fuel Inverter Generator Control Panel 2 3 4 1 5 6 A 7 B 8 1. Circuit Breakers (Push Reset) – Protects the generator against electrical overloads. RECEPTACLES 2. Economy Mode Button – Enables/disables automatic idle control. A 3. Low Oil Warning Indicator Light – When ON, engine will shut down and not run. Check oil level. 4. AC Overload Reset Button – Used to re-energize receptacles after overload fault. B 5.
Controls and Features 200959 - 2000W Dual Fuel Inverter Generator FCC Statement Parts Included Accessories 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 2.3 ft. (0.7 m) LPG Hose with Regulator........................... 1 1a. This device may not cause harmful interference. Engine Oil....................................... 16.9 fl. oz. (500 ml) 1b.
Assembly 200959 - 2000W Dual Fuel Inverter Generator ASSEMBLY Your generator requires some assembly. It must be properly serviced with fuel and oil before operation. If you have any questions regarding the assembly of your generator, call our Technical Support Team at 1-877-338-0999. Please have your serial number and model number available. Unpacking 1. Set the shipping carton on a solid, flat surface. 2. Remove everything from the carton except the generator. 3.
Assembly 200959 - 2000W Dual Fuel Inverter Generator 3. Screw on the gasoline cap and wipe away any spilled fuel. NOTICE CAUTION Check oil level often during the break-in period. Refer to the Maintenance section for recommended service intervals. Use unleaded gasoline with a minimum octane rating of 87 and an ethanol content of 10% or less by volume. CAUTION DO NOT light cigarettes or smoke when filling the tank.
Assembly 200959 - 2000W Dual Fuel Inverter Generator Add Fuel: Propane (LPG) CAUTION 1. Confirm the dial is in the OFF position. Do not allow children to tamper or play with the LPG cylinder or hose connections. 2. If using a new propane cylinder, remove the plastic cap from the cylinder valve. 3. Attach the LPG hose assembly (included) to the propane cylinder valve and hand tighten. CAUTION Use approved LPG cylinders equipped with an OPD (overfilling prevention device) valve.
Operation 200959 - 2000W Dual Fuel Inverter Generator OPERATION – Electrical devices that require a grounded receptacle pin connection will not function if the receptacle ground pin is not functional. Generator Location Neutral Bonded to Frame* WARNING – Neutral circuit IS electrically connected to the frame/ground of the generator.
Operation 200959 - 2000W Dual Fuel Inverter Generator Surge Protection 5. Pull the recoil cord slowly until resistance is felt and then pull rapidly. Electronic devices, including computers and many programmable appliances use components that are designed to operate within a narrow voltage range and may be affected by momentary voltage fluctuations. While there is no way to prevent voltage fluctuations, you can take steps to protect sensitive electronic equipment.
Operation 200959 - 2000W Dual Fuel Inverter Generator 5. Slowly pull the starter cord 3-5 times to prime the engine. NOTICE Keep the dial in “CHOKE” position for only 1 pull of the recoil cord. If generator does not start after first pull, turn the dial to the gasoline “RUN” position for the next three pulls. Too much choke leads to spark plug fouling and engine flooding. This will cause the engine not to start.
Operation 200959 - 2000W Dual Fuel Inverter Generator – DO NOT connect 3-phase loads to the generator. 5. Pull the recoil cord slowly until resistance is felt and then pull rapidly. – DO NOT overload the generator. WARNING Always remember to plug your appliances directly into the generator and do not plug the generator power cord into any electrical outlet or connect to the circuit breaker panel in your home.
Operation 200959 - 2000W Dual Fuel Inverter Generator Parallel Operation To prolong the life of your generator and attached devices, follow these steps to add electrical load: The Champion model 200959 is parallel ready and can be operated in parallel with another Champion unit to increase the total available electrical power. A Champion model 100319 parallel kit (sold separately) is required for parallel operation.
Operation 200959 - 2000W Dual Fuel Inverter Generator Stopping the Engine: Propane (LPG) 1. Turn off and unplug all electrical loads. Never start or stop the generator with electrical devices plugged in or turned on. 2. Let the generator run at no-load for several minutes to stabilize internal temperatures of the engine and generator. 3. Close the fuel valve on the propane cylinder. Operation at High Altitude The density of air at high altitudes is lower than at sea level.
Maintenance 200959 - 2000W Dual Fuel Inverter Generator MAINTENANCE Changing the Engine Oil Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level surface in a clean, dry operating environment. DO NOT expose the unit to extreme conditions, excessive dust, dirt, moisture or corrosive vapors. Change oil when the engine is warm. Refer to the oil specification to select the proper grade for your operating environment. 1.
Maintenance 200959 - 2000W Dual Fuel Inverter Generator Cleaning and Adjusting the Spark Plug Cleaning the Air Filter 1. Remove the maintenance cover. 1. Remove the maintenance cover. 2. Remove spark plug access cap from the top panel. 2. Locate the air filter plastic cover and remove by pinching the clips together and pulling the cover off. 3. Remove the foam element. 3. Remove the spark plug cable from the spark plug. 4. Wash in liquid detergent and water.
Storage 200959 - 2000W Dual Fuel Inverter Generator 6. Replace the spark arrestor if it is damaged. EVERY 50 HOURS OR ANNUALLY 7. Position the spark arrestor on the muffler and attach by reversing the steps from above. Clean air filter Change oil if operating under heavy load or in hot environments CAUTION Failure to clean the spark arrestor will result in degraded engine performance.
Storage 200959 - 2000W Dual Fuel Inverter Generator Short Term Storage (up to 30 days) Long Term Storage (more than 1 year) Gasoline in the gasoline tank has a maximum shelf life of up to 1 year with the addition of properly formulated fuel stabilizers and if stored in a cool, dry place. Gasoline in the carburetor, however, may gum up and clog the carburetor if it isn’t used or drained within 2-4 weeks. For storage over 1 year, the gasoline tank and carburetor must be completely drained of gasoline. 1.
Storage 200959 - 2000W Dual Fuel Inverter Generator Removing from Storage If the generator has been improperly stored for a long period of time with gasoline in the gasoline tank and/or carburetor, all fuel must be drained and the carburetor must be thoroughly cleaned. This process involves technically advanced tasks. For assistance please call our Technical Support Team at 1-877-338-0999.
Specifications 200959 - 2000W Dual Fuel Inverter Generator SPECIFICATIONS Recommended Engine Oil Type 10W-30 Generator Specifications 5W-30 Generator Model............................................ 200959 10W-40 5W-30 Full Synthetic Start Type.................................................... Manual °F -20 °C -28.9 Watts (Starting/Running)............................... 2000/1700 Watts (LPG) (Starting/Running). . ........................ 2000/1530 0 -17.8 20 -6.7 40 4.4 60 15.6 80 26.
Troubleshooting 200959 - 2000W Dual Fuel Inverter Generator TROUBLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Low oil level. Engine will not start. Engine starts but runs roughly. Engine shuts down during operation. Generator cannot supply enough power or overheating. Engine is running but no AC output. Engine hunts or falters. DUAL FUEL MODELS ONLY: Engine will not stop.
WARRANTY 200959 - 2000W Dual Fuel Inverter Generator WARRANTY* Other Exclusions CHAMPION POWER EQUIPMENT 3 YEAR LIMITED WARRANTY This warranty excludes: – Cosmetic defects such as paint, decals, etc. – Wear items such as filter elements, o-rings, etc. Warranty Qualifications – Accessory parts such as starting batteries, and storage covers. To register your product for warranty and FREE lifetime call center technical support please visit: https://www.championpowerequipment.