STORAGE
28
Removing from Storage
If the generator has been improperly stored for a long period of
time with gasoline in the gasoline tank and/or carburetor, all fuel
must be drained and the carburetor must be thoroughly cleaned.
This process involves technically advanced tasks. For assistance
please call our Technical Support Team at 1-877-338-0999.
If the gasoline tank and carburetor were properly emptied of all
gasoline prior to the generator being stored, follow the below
steps when removing from storage.
1. Be sure the fuel dial is in the “STOP” position.
2. Add gasoline to the generator according to Add Fuel.
3. Move the fuel dial to the “RUN” position.
4. After 5 minutes check the carburetor and air filter areas for
any leaking gasoline. If any leaks are found, the carburetor
will need to be disassembled and cleaned or replaced. If no
gasoline leaks are found, turn the fuel dial to the “STOP
position.
5. Check engine oil level and add clean, fresh oil if needed. See
Oil Specifications for proper oil type.
6. Check and clear air filter of any obstructions such as bugs or
cobwebs. If necessary, clean air filter according to Cleaning
the Air Filter.
7. Start the generator according to Starting the Engine.