Instructions / Assembly

200960 - 2000W DUAL FUEL INVERTER GENERATOR
MAINTENANCE
26
NOTICE
Once oil has been added, a visual check should show oil
about 1-2 threads from running out of the fill hole. If using the
dipstick to check oil level, DO NOT screw in the dipstick while
checking.
Cleaning and Adjusting the Spark Plug
1. Remove the spark plug access cover.
2. Remove the spark plug cable from the spark plug.
3. Use a spark plug socket tool (not included), or a
13/16 in. (21 mm) socket (not included) to remove the plug.
4. Inspect the electrode on the plug. It must be clean and not
worn to produce the spark required for ignition.
5. Make certain the spark plug gap is
0.024-0.031 in. (0.6-0.8 mm).
SPARK PLUG GAP
6. Refer to the spark plug types in Specifications when replacing
the plug.
7. Firmly re-install the plug.
8. Attach the spark plug cable to the spark plug.
9. Reinstall the spark plug access cover.
Cleaning the Air Filter
1. Remove the maintenance cover.
2. Locate the air filter plastic cover and remove by pinching the
clips together and pulling the cover off.
3. Remove the foam element.
4. Wash in liquid detergent and water. Squeeze thoroughly dry in
a clean cloth.
5. Saturate in clean engine oil.
6. Squeeze in a clean, absorbent cloth to remove all excess oil.
7. Place the filter in the assembly.
8. Reattach the air filter cover.
9. Reinstall the maintenance cover and tighten the cover screw
securely.