Operator's Manual

Model 100199
TROUBLESHOOTING
35
© 2015 Champion Power Equipment Part No. 101048
Before performing troubleshooting procedures, review SAFETY
section starting on page 5.
Problem Cause Solution
Generator will not
start
Fuel valve turned
off
Turn fuel valve on.
Battery not
charged
Charge battery.
Faulty spark plug Replace spark
plug.
Engine control
module switch off
Turn switch to ATS
or manual.
Active fault code Check fault codes.
Determine what
the fault code is
and remedy the
situation or have
the generator
serviced by
an authorized
Service Dealer or
contact Champion
Customer Service.
Generator starts
but runs rough
Faulty spark plug Replace spark
plug.
Plugged air cleaner Clean or replace
air cleaner.
Fuel pressure
incorrect
Contact authorized
service dealer.
No generator
output
ATS control module
switch off
Turn switch to
auto.
Main circuit
breaker is off
Turn breaker to on.
Transfer switch
turned off
Turn transfer
switch on.
Champion Power Equipment
Toll-free: 1-877-338-0999
Mon-Fri 8:30 AM – 5:00 PM (PST/PDT)