Owner's Manual

9 REV 75537i-20140703
ENGLISH 75537i
ASSEMBLY
Add Engine Oil Contd.
The engine is equipped with a low oil shut-off and
will stop when the oil level in the crankcase falls
below the threshold level.
CAUTION
Check oil often during the break-in period. Refer to
the Maintenance section for recommended service
intervals.
NOTE
The generator rotor has a sealed, pre-lubricated ball
bearing that requires no additional lubrication for
the life of the bearing.
NOTE
Synthetic oil may be used after the 5 hour initial
break-in period. Using synthetic oil does no
increase the recommended oil change interval.
NOTE
We consider the first 5 hours of run time to be
the break-in period for the unit. During the break
in period stay at or below 50% of the running
watt rating and vary the load occasionally to allow
stator windings to heat and cool. Adjusting the
load will also cause engine speed to vary and help
seat piston rings. After the 5 hour break-in period,
change the oil.
NOTE
Weather will affect engine oil and engine
performance. Change the type of engine oil used
based on weather conditions to suit the engine
needs.
NOTE