User's Manual

CHAMPION PUMP
CPS5
CPWH5
CPW5
CPW4R
0
10
20
0 102030405060708090100110120
Gallons Per Minute
Total Head
30
40
in F
T
PUMP PERFORMANCE CURVE
Installation and Operation Manual
Models: CPS5, CPWH5, CPW4,CPW5
Submersible Sump/Effluent/Sewage Pump
Thank you for purchasing this
CHAMPION PUMP! The CPS5/CPWH5
pumps are heavy duty cast iron ½ HP sump/effluent pumps. The CPW4R and CPW5
models are heavy duty cast iron 4/10HP and ½ HP, respectively, sewage pumps
capable of full 2” solids. We back these Champion products with Champion
service and a Champion attitude. Please read, save, and follow these instructions
to ensure Champion performance.
BEFORE OPERATION – Important Product and
Safety Information – WARNINGS – Personal Injury
and/or property damage could result if not adhered to.
! Risk of Electric Shock – Fatal electric shock could occur. Always
disconnect the power source before attempting to install, service,
relocate or check the pump. Never touch pump, pump motor, water, or
discharge piping when pump is connected to electrical power. Never
enter a wet or flooded area, basement, basin, etc. that is in contact with
the pump or electrical circuit before power supply has been
disconnected.
Product Warranty
Date of Manufacture and Warranty Tag is on pump cord.
LIMITED WARRANTY: We warrant to our immediate customer and to the ultimate
consumer that products of our manufacture will be free of defects in material and
workmanship under normal use and service for one year (12 months) from the
date of installation, or 18 months from the date of manufacture, which ever comes
first. We will repair or replace, at our option, to the original purchaser any part or
parts of our product found upon our examination to be defective. Please call
Champion Pump Company, Inc. (419-281-4500) for instructions. Be prepared to
provide the model number, the date code and/or serial number and proof of the
date installed when exercising this warranty. Warranty tag (Required) is on the
pump power cord. All transportation charges on products or parts submitted for
repair or replacement must be paid by purchaser. This limited warranty does not
cover products which have been damaged as a result of accident, abuse, misuse,
neglect, improper installation, improper maintenance, or failure to operate in
accordance with Champion Pump Company, Inc. written instructions. UNDER NO
CIRCUMSTANCES WILL WE BE RESPONSIBLE FOR ANY OTHER DIRECT OR
CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOST PROFITS,
LOST INCOME, LABOR CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION
WHICH DAMAGES ARE CAUSED BY ANY DEFECTS IN MATERIAL AND/OR
WORKMANSHIP AND/OR DAMAGE OR DELAYS IN SHIPMENT. THIS WARRANTY
IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTY,
INCLUDING ANY WARRANTY OF MERCHANTABILTIY OR FITNESS FOR A
PARTICULAR PURPOSE. Some states do not allow limitations on how long an
implied warranty lasts, or do not allow the exclusions or limitations of incidental or
consequential damages, so the above limitations might not apply to you. This
limited warranty gives you legal rights, and you may also have other legal rights
which vary from state to state.
! Pump has not been investigated for use in swimming pool areas or any
area that might reasonably expect aquatic, animal, or human entrance.
Precautions should be taken to prevent such entrance during use.
! Connect only to a properly grounded, grounding type receptacle. Use of
a ground fault circuit interrupter (GFCI) is required for maximum safety.
! All wiring must be performed by qualified electrician in accordance with
all local and national electric code.
! When power source or supply is turned off (in open position) a lock and
tag out should be used to prevent accidental power application or
activation.
! Do not use extension cord or cut off grounding pin. Should be installed
on separate 15 AMP circuit breaker.
! Use only with a properly sized (input AMPS, volts, HP) motor controller.
! Do not use to pump flammable/explosive liquids such as gasoline, fuel
oil, kerosene, and /or chemicals, salt water, etc.
! Do not use pump in an explosive atmosphere or classified as hazardous
per NEC, ANSI/NFPA 70.
! Make sure pump is on hard level bottom in sump, do not set directly on
earth, gravel, or other debris. This could cause excessive wear or
possible jamming and flooding.
! Make sure pump is secure in basin and piping is firmly supported so that
pump cannot move, not allowing liquid level switch to interfere with
basin all or other obstacle preventing proper operation. Flooding or
overheating could occur if not prevented.
CHAMPION PUMP COMPANY Phone: 419-281-4500
12-0011-0000 www.championpump.com
1102 Myers Pkwy. Ashland, Oh 44805 Fax: 419-616-1100
1
4 05/12

Summary of content (2 pages)