Product Manual

100571 - 3500W PORTABLE INVERTER GENERATOR
STORAGE
27
EVERY 50 HOURS OR ANNUALLY
Clean air filter
Change oil if operating under heavy load or in hot
environments
EVERY 100 HOURS OR ANNUALLY
Change oil
Clean/adjust spark plug
Clean spark arrestor
Clean fuel valve filter*
EVERY 250 HOURS
Clean combustion chamber*
Check/adjust valve clearance*
EVERY 3 YEARS
Replace fuel line*
* To be performed by knowledgeable, experienced owners or CPE certified service
centers.
STORAGE
WARNING
To avoid accidental or unintended ignition of your generator
during periods of storage, the following precautions should be
followed:
When storing the generator make sure the EZ Start dial is
set to the “STOP” position.
Short Term Storage (up to 30 days)
Ethanol blended gasoline in the gasoline tank has a maximum
shelf life of up to 1 year with the addition of properly formulated
fuel stabilizers and if stored in a cool, dry place. Gasoline in the
carburetor, however, may gum up and clog the carburetor if it isn’t
used or drained within 2-4 weeks.
If using the generator within 2 weeks, follow the steps according
to Stopping the Engine section.
1. If not using the generator for 2-4 weeks, begin by making
sure all appliances are disconnected from the generator.
2. Start the generator as instructed in Starting the Engine
section.
3. Turn the EZ Start dial to the RUN OUT OF FUEL position.
4. Let the engine run until fuel starvation has stopped the
engine.
5. Turn the EZ Start dial to the “STOP” position
Mid Term Storage (30 days – 1 year)
Ethanol blended gasoline in the tank has a maximum shelf life
of up to 1 year with the addition of a properly formulated fuel
stabilizer and stored in a cool, dry place.
1. Be sure all appliances are disconnected from the generator.
2. Add a properly formulated fuel stabilizer to the gasoline tank.
3. Start engine by following directions in the Starting the Engine
section.
4. Run the generator for 10 minutes so the treated gasoline
cycles through the fuel system and carburetor.
5. Stop engine by turning the EZ Start dial to the RUN OUT OF
FUEL position.
6. After fuel has run out and the engine has stopped, allow the
engine to cool.
7. Turn the EZ Start dial to “STOP” position
8. Remove maintenance cover.
9. Remove the spark plug and pour about a tablespoon of oil into
the cylinder.
10. SLOWLY pull the recoil to rotate the engine to distribute and
lubricate the cylinder.
11. Re-install the spark plug and spark plug wire.
12. Re-install the maintenance cover.