Installation Manual

5
Ensure the blades will be at least
30 in. from any obstructions. Also
check the downrod length to ensure
the blades will be at least 7 ft. above
the oor.
Downrod Mounting is best suited for
ceilings 8 ft. or higher. For very high
ceilings, use a longer downrod (not
included).
Angle Mounting is best suited for
angled or vaulted ceilings. A longer
downrod is sometimes necessary to
ensure proper blade clearance. Ensure
the ceiling angle is not steeper than 16°.
Flushmount is not available on this fan.
Closemount is best suited for ceilings
lower than 8 ft.
7 ft.
min.
30 in.
min.
Downrod Mounting
Flushmount Closemount
Angle Mounting
3. Choose suitable location.2. Choose mounting option.
PREPARATION
Turn the power off to the fan at the
breaker box and the wall switch.
1. Turn power off.
Failure to disconnect the power supply
prior to installation may result in serious
injury or death.
See pages 20-21 for complete description
of cautions and warnings.