Operation Manual

48
Operation of appliances
?
@972<2M0
If you are not heating your vehicle when winter approaches, you must empty all clean water and waste water circuits and
the water heater, to prevent any damage which will not be covered by the guarantee.
Waste water
Be careful where you discard waste water.
The wastewater reservoir is evacuated with the help
of a knifegate valve that allows quick draining of the
reservoir.
Locate the valve on the body
Manipulation handle (pull towards you for opening)
Knife gate valve
Insulation
Certain of our models feature specific insulation of
the wastewater reservoirs, which are found under the
vehicle chassis.
Water pump
For the Shurflo pump models, the tank must be completely
drained during the winter. Draining is done by opening
the drain tap or by opening all the taps and operating
the pump (15 minutes on, 15 minutes off) until the tank
is empty.
Next, disconnect the pump’s inlet and outlet pipes,
preparing a container to catch any residual water.
Switch the pump on to evacuate any water remaining
in the pump. To avoid problems due to freezing, do not
reconnect the pipes during the winter, and leave all the
taps open.