2. Average Mode
Average mode is displayed on the LCD screen
Pushing the Power Switch will show the memory
block number where readings are to be stored.
The block number will flash for a few seconds.
Average mode allows 30 blocks total, each block is
dependent on the time the power switch is first
pressed and then released.
It is not requried to use all the 30 memory blocks to
avail of this mode. It is dependent on the usage of
the tachometer.
When N30 is displayed on the screen, the unit has
reached the maximum allowed memory block number.
When the “FULL” indicator is displayed on the LCD
screen, no additional readings will be stored.
Unit of Measure Indicator (RPM) will flash
continuously while taking measurements. Once
the Unit of Measure stops flashing, the
tachometer will stop updating and no additional
measurements will be read. Pressing the Power
Switch will advance the memory block location
and resume measurements.
The display updates every 1 second.