Specifications

Subject to change – 2015/03
26
è Internet: www.festo.com/catalog/...
Valve terminals MPA-L
Key features – Assembly
Valve terminal assembly
Sturdy terminal assembly thanks to:
Four through-holes for wall
mounting
Additional mounting brackets
H-rail mounting
-H- Note
If the terminal is subject to strong
vibrations or shock loads, use
additional mounting brackets of the
type VMPAL-BD for wall mounting.
These should be attached to the valve
terminal every 13 cm (one mounting
bracket every 10 valve positions).
Wall mounting – Multi-pin plug connection
The MPA-L valve terminal is screwed
onto the mounting surface using four
M4 or M6 screws. The mounting holes
are on the multi-pin plug connection
and on the right-hand end plate.
Optional mounting brackets are also
available.
Wall mounting – Fieldbus connection (CPX terminal)
The MPA-L valve terminal is screwed
onto the mounting surface using four
M4 and two M6 screws or using six
M6 screws. The mounting holes are
on the left-hand and right-hand end
plate and on the pneumatic interface.
Optional mounting brackets are also
available.
H-rail mounting
A
B
The MPA-L valve terminal is
attached to the H-rail (see arrow A).
The terminal is then swivelled onto
the H-rail and secured in place with
the clamping component
(see arrow B).
The following MPA-L mounting kit is
required for H-rail mounting of the
valve terminal:
With multi-pin plug connection:
CPX-CPA-BG-NRH
With fieldbus connection
(CPX terminal):
VMPAF-FB-BG-NRH
This enables mounting of the valve
terminal on an H-rail to EN 60715.
-H- Note
The mounting kits (see above) only
lock the valve terminal in horizontal
mounting position.