Specifications

Subject to change – 2015/03
36
è Internet: www.festo.com/catalog/...
Valve terminals MPA-L
Key features – Electrical components
Pin allocation for electrical multi pin-plug connection – Flat cable, 40-pin
Pin Address/coil Pin Address/coil Pin Address/coil
1 0 18 17 35 0 V
1)
2 1 19 18 36 0 V
1)
3 2 20 19 37 0 V
1)
4 3 21 20 38 0 V
1)
5 4 22 21 39 0 V
1)
6 5 23 22 40 0 V
1)
7 6 24 23
-H- Note
The drawing shows the view onto the
pins of the flat cable plug.
The flat cable connection is
established using plug connectors,
in accordance with
DIN EN 60603-13:1998-09
(NECU-FCG40-K).
è Internet: necu
8 7 25 24
9 8 26 25
10 9 27 26
11 10 28 27
12 11 29 28
13 12 30 29
14 13 31 30
15 14 32 31
16 15 33 0 V
1)
17 16 34 0 V
1)
1) 0 V for positive switching control signals; connect 24 V for negative switching control signals; mixed operation is not permitted.
Pin allocation for electrical multi pin-plug connection – Terminal strip, 33-pin
Pin Address/coil Pin Address/coil Pin Address/coil
1 0 16 15 31 30
2 1 17 16 32 31
3 2 18 17 33 0 V
1)
4 3 19 18
-H- Note
The drawing shows the view onto the
pins of the terminal strip.
Cables with the following
specifications can be connected:
Cable cross section
0.08 … 0.5 mm
2
Insulation 5 … 6 mm
5 4 20 19
6 5 21 20
7 6 22 21
8 7 23 22
9 8 24 23
10 9 25 24
11 10 26 25
12 11 27 26
13 12 28 27
14 13 29 28
15 14 30 29
1) 0 V for positive switching control signals; connect 24 V for negative switching control signals; mixed operation is not permitted.