User manual

Section 4: Maintenance
4-10 Mirage S+/HD/WU, Matrix S+/HD/WU, Christie HD/DS+/DW, DLV User Manual
020-100001-07 Rev. 1 (11-2009)
1.
2.
3.
4.
5.
6.
7.
8.
Lamp Hours
Lamp S/N
Lamp Message
Lamp Limit
Lamp Mode
Power
Intensity
Optical Aperture
Lamp History
Change Lamp
Lamp
0
?
1000
Power
500
0
3
Lamp S/N
S/N
5679
1234
Hours
1001
0
Lamp History
New serial# entry
automatically updates
Lamp History...
...and resets Lamp
Hour
s
to “
0
IMPORTANT: If you neglect to enter a serial number, the lamp timer will not
reset to “0” and will therefore be inaccurate. The lamp life limit may then expire
prematurely.
WARNING
Use Christie approved
filters ONLY.
The two filters located at the front
and left side of the projector should
be replaced whenever the lamp is
replaced. If you are working in an
extremely dusty environment you
may want to replace the filters sooner.
Use the filters provided in the Christie
approved Lamp and Filter Kit for your
specific projector model.
1. TURN OFF THE PROJECTOR, COOL and UNPLUG
Before removing or installing a filter, turn off the projector and allow it to cool for
five minutes before unplugging.
2. REMOVE FILTER ACCESS
PANELS
Loosen the captive screw(s) on the filter
access panels using a #2 Phillips
screwdriver. (Front access panel located
to the left of the lens – one screw. Left
side access panel – three screws. See
Figure 4.6.
Figure 4.6. Lamp Menu
Filter Replacement
Procedure
Figure 4.7. Filter Location
Figure 4.8. Remove Filter Access Panels