Setup guide

Installation and Setup
CP2210 Setup Guide 2-9
020-100524-04 Rev. 1 (05-2014)
1. Install the M-MALM according to the instructions provided with the kit. Ensure the primary lens is
optimized first for best optical alignment, offset and boresight.
2. Loosen the holding clamp on the auxiliary lens mount and adjust rotation of the whole anamorphic lens so
the image remains perfectly square with anamorphic in and out.
3. Adjust location of anamorphic lens so the image does not shift left or right with the anamorphic lens IN
and OUT.
4. Adjust location of anamorphic lens so the image passes through the center as much as possible without
vignetting or reducing side or corner brightness, especially in wide angle projection.
5. With the anamorphic lens not in place, re-focus the primary lens. The goal is good focus at center and on
all sides. Now add the anamorphic lens and check focus again.
6. If center-to-edge horizontal focus in the image needs improvement, focus the anamorphic lens - rotate its
focus barrel as needed.
2.10 Install the Optional Wide Converter Lens
1. Install the Auxiliary Lens Mount and WCL according to the instructions provided with the kit. Ensure the
primary lens is optimized first for best optical alignment, offset and boresight.
2. Image shift: Adjust the vertical and horizontal position of the WCL to align it with the already adjusted
prime lens.
3. Pitch Adjustment: Adjust pitch, either up or down to equalize the top and bottom clearance to the prime
lens barrel.
4. Yaw Adjustment: Adjust yaw so the clearance between both lens barrels is equal from side-to-side.
2.11 Install the Optional Motorized Auxiliary Lens Mount (MALM)
The M-MALM assembly is an optional hardware
component, that you can use used to switch from
flat to scope formats. The MALM is secured to the
cinema projector base and supports either a 1.25x
anamorphic lens or a 1.26x wide converter lens
(WCL). A 9-pin subminiature D cable connected to
the input panel is used to communicate with and
control the MALM. For more information, see the
Motorized Auxiliary Lens Mount (M-MALM)
Installation Instruction Sheet (P/N: 020-100188-
xx).
2.12 Install the Lamp
Only personnel trained specifically by Christie on lamp replacement and lamp safety may
handle the lamp. High-pressure lamp may explode if improperly handled.
Figure 2-7 MALM
DANGER