Setup guide

3-2 CP2210 Setup Guide
020-100524-04 Rev. 1 (05-2014)
Connect Devices to the cinema projector
3.2 Connect a Communications Device
The RS232 PIB port located on the PIB faceplate utilizes Christie-proprietary
protocol and is intended for Christie accessories or automation controllers only.
To communicate with the cinema projector, connect the equipment to an Ethernet hub or switch.
Figure 3-2 Connecting Communications
3.3 Connect Devices to the SCCI Port
The Simple Contact Closure Port (SCCI) port is a DB-9 (male) connector is located on the PIB input panel and
is used to control a limited set of cinema projector functionality through contact closures. This table lists the
control functions available through the SCCI:
Table 3.1 SCCI Connector Pinouts
PIN SIGNAL NAME DIRECTION DESCRIPTION
1 +5V Standby Out Current limited 5VDC supply
2 Lamp ON In cinema projector at Power On mode,
lamp is ON
3 +5V Standby Out Current limited 5VDC supply
4 Lamp OFF In cinema projector at full power, lamp is
OFF
5 +5V Standby Out Current limited 5VDC supply
6 Douser Closed In Close douser
7 Douser Open In Douser open