Setup guide

6-8 CP2210 Setup Guide
020-100524-04 Rev. 1 (05-2014)
Maintenance
6.11 Replace the Lens
1. Tap and hold the red power button on the TPC Main panel to turn the lamp and cinema projector off.
2. Allow the lamp to cool for a minimum of 10 minutes.
3. Unplug the cinema projector.
Figure 6-5 Lens Assembly
4. Install the lens cap and release the lens clamp by pushing it up (Figure 6-6).
Figure 6-6 Release Lens Clamp
5. If necessary, remove the 2 cap screws securing the lens to the lens mount using a 5mm hex key (Figure 6-
6). The cap screws are only needed when the cinema projector is ceiling mounted.
6. Pull the lens out of the lens mount. The lens, motorized zoom and focus connectors disconnect when the
lens is pulled straight out of the mount.
7. Remove the small rear cap. Keep the front cap on.
8. Align the mounts on the lens connector with the lens mount. Insert the lens until it connects with the
magnets on the mount. Once the lens makes contact with the magnetic plates it will be seated correctly and
the connector for motorized zoom and focus will be properly connected (Figure 6-7).
9. Secure the lens clamp by pushing it down to the closed position.