Setup guide

7-2 CP2210 Setup Guide
020-100524-04 Rev. 1 (05-2014)
Troubleshooting
7.3 Lamp Suddenly Turns Off
•Tap Menu > Advanced Setup > Lamp Power/LiteLOC Setup. Increase the lamp power.
•Tap Menu > Status and then Interlocks in the left pane. Review and correct all interlock failures.
If EVB errors occur, check the door interlock.
•Tap Menu > Status and then Temperatures in the left pane. Verify if the DMD temperatures are too high. If
the temperatures are too high, cool the cinema projector. Ensure the cinema projector is properly ventilated,
the air filters are not blocked, and the liquid cooling reservoir has coolant.
Replace the lamp.
7.4 Flicker, Shadows, or Dimness
Ensure the douser is open.
Run a LampLOC™ adjustment.
Verify that a LampLOC™ adjustment is not in progress.
•Tap Menu > Advanced Setup > LampPower/LiteLOC™ Setup. Monitor the Power % field to determine
if the power is consistent or varying. Increase the lamp power. Lamps which are near end of service may not
operate reliably at a lower power setting.
Fold mirror misalignment. Contact your Christie accredited service technician to resolve the issue.
Integrator rod misalignment. Contact your Christie accredited service technician to resolve the issue.
7.5 LampLOC™ Not Working
If the Do Auto option is not working, tap Menu > Advanced Setup > LampLOC™ Setup and adjust the
lamp position manually. Observe screen brightness by adjusting the XYZ values or use a light meter to check
for changes in brightness.
7.6 LiteLOC
Not Working
•Tap Menu > Advanced Setup > LampPower/LiteLOC™ Setup. Tap Enable LiteLOC
.
If the lamp power is at the maximum setting to maintain a LiteLOC™ setting, LiteLOC™ is automatically
disabled. Reduce the LiteLOC™ setting, or install a new lamp.
7.7 TPC
If the TPC fails to initialize, restart the cinema projector.
If the TPC display is blank, ensure the TPC is on by opening the flap at the back of the TPC and verify the
grey button in the bottom left corner is ON.
If the locations of button presses on the screen are misinterpreted, the TPC screen may need recalibrating.
Tap Menu > Administrator Setup > Preferences. Tap Calibrate Screen and follow the onscreen instruc-
tions.