5.3 Reference Equipment for Type Approval
128
t EXS62-W_EXS82-W_HID_v01.200ee 2022-09-07
Public/ Released
Page 126 of 144
5.3 Reference Equipment for Type Approval
The Thales reference setup submitted to type approve EXSx2-W (including a special approval
adapter for the DSB75) is shown in the following figure
1
:
Figure 70: Reference equipment for type approval
1. For RF performance tests a mini-SMT/U.FL to SMA adapter with attached 6dB coaxial attenuator is cho-
sen to connect the evaluation module directly to the GSM/LTE/GNSS test equipment instead of employ-
ing the SMA antenna connectors on the EXSx2-W-DSB75 adapter as shown in Figure 70. The following
products are recommended:
Hirose SMA-Jack/U.FL-Plug conversion adapter HRMJ-U.FLP(40)
(for details see http://www.hirose-connectors.com/ or http://www.farnell.com/
Aeroflex Weinschel Fixed Coaxial Attenuator Model 3T/4T
(for details see http://www.aeroflex.com/ams/weinschel/pdfiles/wmod3&4T.pdf)
DSB75
DSB75 Adapter
SIM Card
SMA
SMA
SMA
USB
PC
Power
Supply
LTE / GSM
Base Station
GNSS
Antenna
ASC0
Main
Antenna
Eval_Board
EXSx2-W
Eval_Board
EXSx2-W
ASC1