Specifications

Table Of Contents
Cinterion
®
EXS62-W/EXS82-W Hardware Interface Description
2.4 Sample Application
61
t EXS62-W_EXS82-W_HID_v01.200ee 2022-09-07
Public/ Released
Page 61 of 144
2.4.1 Sample Level Conversion Circuit
Depending on the micro controller used by an external application EXSx2-W‘s digital input and
output lines (i.e., ASC0, ASC1) may require level conversion. The following Figure 32 shows a
sample circuit with recommended level shifters for an external application‘s micro controller
(with VLOGIC between 3.0V...3.6V). The level shifters can be used for digital input and output
lines with V
OH
max=1.85V or V
IH
max =1.85V. The sample circuit is not optimized for low current
consumption.
Figure 32: Sample level conversion circuit
5V tolerarant
Low level input
Low level input
Low level input
VCC
5V tolerant
VCC
E.g.,
74VHC1GT50
74LV1T34
E.g.,
74LVC2G34
NC7WZ16
External application
Micro controller
VLOGIC
(3.0V...3.6V)
Input lines,
e.g., µRXD, µCTS
Output lines,
e.g., µTXD, µRTS
V180 (1.8V)
Digital output lines,
e.g., RXDx, CTSx
Wireless module
Digital input lines,
e.g., TXDx, RTSx