3.2 Power Up/Power Down Scenarios
102
t EXS62-W_EXS82-W_HID_v01.200ee 2022-09-02
Public/ Released
Page 70 of 144
A low level of the V180 signal - in addition to the regular "^SHUTDOWN" URC issued by the
module - indicates that the switch off procedure has completed and the module has entered
the Power Down mode.
Note: Using the command AT^SMSO=”fast”, it is possible to trigger a fast shutdown procedure,
i.e., shutting down without gracefully deregistering from the network thus saving time between
T0 - T2. Same as with the fast shutdown procedure triggered with the FST_SHDN line (see
Section 2.1.11.3), there will be no ^SHUTDOWN URC in this case. The timings for module
switch off using AT^SMSO=”fast” are listed below in Table 16.
Table 15: Switch off timing values (AT^SMSO)
Timing Description Value Unit
T0 - T1 AT^SMSO – URC 247.15
1
(depending on
network)
1. Value is dependent on network, and may take up to 5 seconds for LTE Cat NB1/2 networks.
ms
T1 - T2 URC – V180 14.19
T2 - T3 V180 – V180 (low) 1.53
T3 - T4 V180 (low) – VCORE 1.64
Table 16: Switch off timing values (AT^SMSO=”fast”)
Timing Description Value Unit
T0 - T1 AT^SMSO=”fast” – URC 1.62 ms
T1 - T2 URC – V180 8.54
T2 - T3 V180 – V180 (low) 1.46
T3 - T4 V180 (low) – VCORE 1.74