Specifications

Table Of Contents
Cinterion
®
EXS62-W/EXS82-W Hardware Interface Description
3.2 Power Up/Power Down Scenarios
102
t EXS62-W_EXS82-W_HID_v01.200ee 2022-09-02
Public/ Released
Page 71 of 144
3.2.5 Automatic Shutdown
Automatic shutdown takes effect if the following event occurs:
The EXSx2-W board is exceeding the critical limits of overtemperature or undertemperature
(see Section 3.2.5.1)
Undervoltage or overvoltage is detected (see Section 3.2.5.2 and Section 3.2.5.3)
The automatic shutdown procedure is equivalent to the power-down initiated with an AT com-
mand, i.e. EXSx2-W logs off from the network and the software enters a secure state avoiding
loss of data.
3.2.5.1 Thermal Shutdown
The board temperature is constantly monitored by an internal NTC resistor located on the PCB.
The values detected by the NTC resistor are measured directly on the board and therefore, are
not fully identical with the ambient temperature.
Each time the board temperature goes out of range or back to normal, EXSx2-W instantly dis-
plays an alert (if enabled).
URCs indicating the level "1" or "-1" allow the user to take appropriate precautions, such as
protecting the module from exposure to extreme conditions. The presentation of the URCs
depends on the settings selected with the AT^SCTM write command (for details see
[1]):
AT^SCTM=1: Presentation of URCs is always enabled.
AT^SCTM=0 (default): Presentation of URCs is enabled during the 2 minute guard period
after start-up of EXSx2-W. After expiry of the 2 minute guard period, the presentation of
URCs will be disabled, i.e. no URCs with alert levels "1" or ''-1" will be generated.
URCs indicating the level "2" or "-2" are followed by an orderly shutdown after 5 seconds
unless the temperature returns to a valid operating level ("1", "0", "-1") or or the shutdown
ability was disabled with AT^SCFG, "MEopMode/ShutdownOnCritTemp",<sdoct>. The pre-
sentation of these URCs is always enabled, i.e. they will be output even though the factory
setting AT^SCTM=0 was never changed.
The maximum temperature ratings are stated in Section 3.5. Refer to Table 17 for the associ-
ated URCs.
Table 17: Temperature dependent behavior
Sending temperature alert (2min after module start-up, otherwise only if URC presentation enabled)
^SCTM_B: 1 Board close to overtemperature limit.
^SCTM_B: -1 Board close to undertemperature limit.
^SCTM_B: 0 Board back to non-critical temperature range.
Automatic shutdown after 5 seconds (URC appears no matter whether presentation was enabled or not)
^SCTM_B: 2 Alert: Board equal or beyond overtemperature limit. EXSx2-W switches off.
^SCTM_B: -2 Alert: Board equal or below undertemperature limit. EXSx2-W switches off.