Table 20: General current consumption ratings (EXSx2-W)
Description Conditions Typical rating Unit
EXS62-W EXS82-W
I
BATT+
1
(i.e., sum of
BATT+
BB
and
BATT+
RF
2
)
1. With an impedance of Z
LOAD
=50Ω at the antenna connector, Measured at 25°C at 3.8V.
2. BATT+
RF
is available with EXS82-W only.
OFF State
supply cur-
rent
POWER DOWN 14 14.7 µA
Airplane
mode
(CFUN = 4)
UART (RTS) active 8.29 8.07 mA
UART (RTS) inactive 0.71 0.74 mA
Table 21: Current consumption ratings Cat M1 (EXSx2-W)
Description Conditions Typical rating Unit
EXS62-W EXS82-W
I
BATT+
1
(i.e., only
BATT+
BB
)
Average
LTE CAT-
M1 supply
current
SUSPEND
2
Power save mode (EXS62-W) 3.3 4.3 µA
RRC idle
(SLEEP)
2
DRX=256 1.07 1.06 mA
DRX=128 1.52 1.54 mA
DRX=64 2.43 2.40 mA
20,48s
eDRX
3,84s paging win-
dow (DRX=1.28s)
0.80 0.82 mA
81,92s
eDRX
2,56s paging win-
dow (DRX=1.28s)
0.59 0.62 mA
163,84s
eDRX
3,84s paging win-
dow (DRX=1.28s)
0.58 0.63 mA
163,84s
eDRX
10,24s paging win-
dow (DRX=1.28s)
0.62 0.67 mA
RRC idle
(SUSPEND)
2
81,92s
eDRX
2,56s paging win-
dow (DRX=1.28s)
0.65 0.64 mA
163,84s
eDRX
3,84s paging win-
dow (DRX=1.28s)
0.35 0.34 mA
163,84s
eDRX
10,24s paging win-
dow (DRX=1.28s)
0.43 0.42 mA
Connected
DRX
3
Short C-DRX 59 56 mA