Specifications

Table Of Contents
Cinterion
®
EXS62-W/EXS82-W Hardware Interface Description
3.4 Power Supply
102
t EXS62-W_EXS82-W_HID_v01.200ee 2022-09-02
Public/ Released
Page 89 of 144
I
BATT+
1
(i.e., only
BATT+
BB
)
Average
LTE NB1/2
supply
current
RRC connected
Active Transmission
UL RMC, single
tone mode (1sub-
carrier),15KHz
spacing
3
Band28, 20dBm 175 193 mA
Band66, 20dBm 226 202 mA
Band71, 20dBm 175 189 mA
Band85, 20dBm 173 189 mA
Band1, 0dBm 63 64 mA
Band2, 0dBm 62 64 mA
Band3, 0dBm 62 63 mA
Band4, 0dBm 61 63 mA
Band5, 0dBm 61 63 mA
Band8, 0dBm 61 63 mA
Band12, 0dBm 60 62 mA
Band13, 0dBm 61 62 mA
Band18, 0dBm 61 62 mA
Band19, 0dBm 61 62 mA
Band20, 0dBm 61 62 mA
Band25, 0dBm 62 64 mA
Band26, 0dBm 61 63 mA
Band28, 0dBm 61 63 mA
Band66, 0dBm 62 63 mA
Band71, 0dBm 60 61 mA
Band85, 0dBm 60 62 mA
RRC connected
Active Transmission
UL RMC, multi- tone
mode (12 subcar-
rier),15kHz spac-
ing
3
Band1, 20dBm 61 59 mA
Band2, 20dBm 60 58 mA
Band3, 20dBm 65 62 mA
Band4, 20dBm 62 59 mA
Band5, 20dBm 59 58 mA
Band8, 20dBm 61 62 mA
Band12, 20dBm 58 57 mA
Band13, 20dBm 59 58 mA
Band18, 20dBm 59 59 mA
Band19, 20dBm 60 60 mA
Band20, 20dBm 61 61 mA
Table 22: Current consumption ratings Cat NB1/2 (EXSx2-W)
Description Conditions Typical rating Unit
EXS62-W EXS82-W